Expanding and assigning parameters to the device
6.4 Drives (HDD/SSD)
Note
If the device is permanently installed, mounted on telescopic rails, it can only be subjected to
the vibration stresses described below during operation.
The maximum permitted power loss of the expansion cards is 75 W.
You can install the HDD or SSD in the drive cage at various mounting locations.
You can find information on the mounting locations under:
• Drive cage (Page 13)
If HDD/SSDs are installed in one of the mounting locations, these may be exposed to the
following vibration stresses during operation:
• For HDD:
– 10 to 58 Hz: 0.015 mm
– 58 to 200 Hz: 1.96 m/s
• For SSD:
– 10 to 58 Hz: 0.0375 mm
– 58 to 200 Hz: 4.9 m/s
Vibrations above 500 Hz are not permitted.
6.4.2

Removing the drive module

Requirement
• The device is fully disconnected from the line voltage, see Switching off the device
(Page 44).
• PH2 screwdriver