IECEx approval
For the device with "IECEx" marking, the following approvals apply according to the following
standards.
• Standards:
– IEC 60079-0:2017
– IEC 60079-7: 2017
• Approvals:
• Specific conditions of use (for IECEx):
– The equipment shall only be used in an area of at least pollution degree 2, as defined
– The equipment shall be installed in an enclosure that provides a minimum ingress
– Transient protection shall be provided that is set at a level not exceeding 140 % of the
– The equipment is acceptable for use in different ambient temperature ranges (Ta: 0˚C
WEEE label (European Union)
Disposal instructions, observe the local regulations and the section "Recycling and disposal
(Page 58) ".
7.2

Directives and declarations

7.2.1

Electromagnetic compatibility, Industrial and Residential Areas

Electromagnetic compatibility
This product meets the requirements of EC Directive 2014/30/EU "Electromagnetic
Compatibility".
SIMATIC IPC227G
Operating Instructions, 07/2022, A5E50059933-AC
II 3 G
IECEx certificate
number
in EN 60664-1.
protection of IP 54 in accordance with EN 60079-0.
peak rated voltage value at the supply terminals to the equipment.
to 45˚C /50˚C /55˚C) depending on CPU types, mounting positions and NVRAM
availability. Users shall access Operating Instructions (document no. A5E50059933-AB)
Ambient Conditions section for details."
Technical specifications
7.2 Directives and declarations
Ex ec IIC T4 Gc
IECEx UL 21.0008X