Connecting the unit

6.5.3 Connecting a waste water line with an unobstructed discharge

INFORMATION
Prerequisite The waste water line complies with the specifications (see "Unit and

6.6 Making the exhaust air connection

NOTICE
NOTICE
44
b
a
c
d
Image: Connecting a waste water line with an unobstructed discharge
a Waste water connection
b Waste water line
c Funnel waste trap
Connect only the discharge funnel if a waste water trap is installed in the
waste water system.
connection data")
1. Connect the discharge funnel with waste trap to the sewer system.
2. Connect the waste water line to the unit and extend it to the
discharge funnel.
3. Secure waste water line with pipe clamps.
4. Install outlet of the waste water line 20 mm above the discharge
funnel.
5. Fill the discharge funnel with tap water.
6. Fill out the Start-up operation report.
When installing the unit under a ventilation system, observe the
regional regulations for air conditioning systems.
Risk of property damage from fouling of the outgoing air ducts
• Not connect the exhaust airline directly to the ventilation system.
Risk of corrosion damage from condensate
• Install the exhaust air line such that condensate cannot collect.
Installation instructions
b
f
a
e
d
d Waste water system
e Waste water system siphon
f Discharge funnel