Basic setting of control (Advanced)
Basic setting
Condensation-hood
after-running time
Generator mode
Steam elimination
Duration of audible
signal
Parameter
Standard
s
value
5
60
45
0
48
1
6
20
Installation instructions
Range of
Explanation
adjustment
0 – 600 s
Time extension for the condensation hood,
after the cooking chamber door has been
opened
0 = No
When a generator is used to supply
electricity
1 = Yes
0 = Low
Sets the steam elimination level
1 = Normal
2 = High
0 = Signal off
Duration of the audible signal
1 — 180 s
Description of the unit