Henny Penny FlexFusion ELECTRIC GOLD COMBI FGE-615 Installation Instructions Manual page 16

Table of Contents

Advertisement

Description of the unit
Basic setting of the control
Basic setting
Supply voltage
Altitude
Volume of audible
signal
Unit of temperature
Unit of volume
80 % power
Power optimization
system
16
Parameter
Standard
s
value
14
400
2
0
33
0
1
0
34
0
35
0
3
0
42
0
Installation instructions
Range of
Explanation
adjustment
100 — 500 V
Enter the local, mean voltage between the
line conductors.
0 = 0 — 999 m
Request the altitude above sea level from
(3277 ft)
the local weather station. If the altitude is
unknown, enter 0 — 999 m (3277 ft).
1 = 1000 m (3280
ft) — 1999 m
(6557 ft)
2 = 2000 m (6560
ft) — 2499 m
(8197 ft)
3 = 2500 m (8200
ft) or higher
0 = Quiet
Setting the volume
1 = Loud
0 = °C
Celsius (°C)
1 = °F
Fahrenheit (°F)
0 = ml
Milliliter (ml)
1 = fl.oz
Fluid ounce (fl.oz.)
0 = Imperial
Imperial fluid ounce
(fl.oz.)
1 = U.S. (fl.oz.)
U.S. fluid ounce
1 = 80 %
Power can be limited to 80 % (for special
applications).
0 = 100 %
1 = On
If a power optimization system is
connected, "On" must be selected for the
0 = Off
unit to heat.

Advertisement

Table of Contents
loading