User Guide
Table 4-7
Remote Boost
Delay Boost
ART
Calibration
Diagnostics
Firmware Update
Bake Out Cycle 1
Bake Out Cycle 2
Bake Out Cycle 3
Bake Out Cycle 4
Bake Out Cycle 5
Soft Start
Soft Start to Manual
Standby
Soft Start to Remote
Standby
Stage x Active (Heating) The system increases the temperature to the stage setpoint for all zones
Stage x Active (ART)
Stage x Soaking
(Heating)
Stage x Active (Cooling) All zones assigned to stage x decrease their temperature to the stage
Stage x Soaking
(Cooling)
Stage 4 Running
Indefinitely
System Modes
v 1.0 — February 2020
System Modes (Continued)
System Mode
An external signal has activated the remote boost mode and the system
adjusts the temperature to the remote boost setpoint.
The system is delayed for a set duration of time before it changes to
Remote Boost mode.
The Active Reasoning Technology (ART) tuning process is active.
Shown during thermocouple input calibration for the zones.
The mold diagnostics process is active.
Shown during a firmware update on selected control cards.
Shown as the system is bakes out moisture in the mold. This is the first
bake of the mold.
Shown as the system is bakes out moisture in the mold. This is the second
bake of the mold.
Shown as the system is bakes out moisture in the mold. This is the third
bake of the mold.
Shown as the system is bakes out moisture in the mold. This is the fourth
bake of the mold.
Shown as the system is bakes out moisture in the mold. This is the fifth
bake of the mold.
The system gradually increases the temperature of all zones to a setpoint
in an even process.
The system was put into Manual Standby while the system was in the Soft
Start process.
During the Soft Start process, an external signal was activated that tells
the system to increase the temperature of all zones to the Remote
Standby setpoint.
assigned to stage x (1-4).
The ART tuning process is applied only on the zones assigned to stage x.
After the temperature has increased, the system keeps the zones'
temperature at the stage x setpoint until the soak timer completes.
setpoint.
After the temperature has decreased to the stage setpoint, the system
keeps the zones' temperature at the stage x setpoint until the soak timer
completes.
The system stays in stage 4 until the user touches the Start button to
increase the temperature(s) of the zones to the operation setpoint.