Husky Altanium Delta5 User Manual page 220

Table of Contents

Advertisement

Figure 15-14 Retaining Clip and Cable Removal
11. Use a 4 mm right angle Allen key or hex wrench to remove the two bottom socket cap
IMPORTANT!
Only loosen the top fasteners. The top mounting holes in the bracket holding the touch
monitor are slotted and allow the monitor to be removed without removing the top
fasteners completely.
12. Use the 4 mm right angle Allen key or hex wrench to loosen the two top socket cap
208
screws from the retaining plate that secures the touch monitor to the pedestal. Refer to
callout 9 in
Figure
15-15.
screws from the retaining plate that secures the touch monitor to the pedestal. Refer to
callout 10 in
Figure
15-15.
Do not remove the screws.
v 1.0 — February 2020
Altanium Delta5
Remove and Replace the Touch Monitor

Advertisement

Table of Contents
loading