Husky Altanium Delta5 User Manual page 128

Table of Contents

Advertisement

Table 10-5
Allow Monitor Regulation for
Selection
Exclude Monitor Zones from
At-Temperature
Wattage Voltage
Supply Configuration
Global Output Power Limit
Earth Leakage Fault Enable
Earth Leakage Limit
Display Earth Leakage Reading When ICC
Circuit Overload Enable
Circuit Test Enable
Auto Power Limiting Enable
Circuit Test State 4 Power
Level
Display Causes and Solutions
Enable
Display Failure Data
116
v 1.0 — February 2020
System Setup Screen - Heats Setup - Monitoring (Continued)
Item
Enables the parameter that lets the system change the regulation
mode to "Monitor" for zones in the Quick Set screen.
Enables the parameter that lets the system exclude zones that are
set to "Monitor" regulation from the "At Temperature" condition.
Insert the designed voltage rating of the heaters so the system can
accurately calculate Watt Voltage.
Used to select the supply configuration parameter: Delta 3PH,
Wye 3PH+N, Single Phase, or Integrated TX.
Used to control the maximum output power applied to each zone.
Enable or disable the earth leakage check.
For ICC
limit when the diagnostic process for a zone is complete. The
control card uses a percentage of the current measured during
the test to make the decision when an earth leakage error occurs.
The parameter range is 0 to 100%. The default value is 10%.
For ICC
adjustable range from 1 to 999 mA. The default value is 500 mA.
Enables or disables the circuit overload error. This shows only if
3
ICC
cards are installed.
Enables or disables the circuit test for ICC
When enabled, the controller automatically adjusts the output
power limit values on zones that have oversized heaters attached.
This setting is disabled by default.
This is the power level that is applied during pre-state 4 when the
control card calculates the current during circuit test. The range is
from 20% to 50% and the default value is 50%.
When enabled, the controller stops the system and alerts the user
that failures were detected during circuit test. The controller
shows a dialog window of possible causes and solutions data.
Refer to
This button becomes enabled when the system has completed
the circuit test and failures have been found. Touch the button to
see past test results, so you do not have to run the circuit test
again. If no failures are found, then the button stays disabled.
Refer to
Description
2
cards, a percentage used to calculate the earth leakage
3
cards, the value is displayed in milliamps and has an
3
cards are installed, this shows the earth leakage.
Section
15.8.
Section
15.8.
Altanium Delta5
3
cards.
Heats Setup - Monitoring

Advertisement

Table of Contents
loading

Table of Contents