4. Check:
• Continuity
(with the pocket tester)
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
TIP
• If there is no continuity, clean the terminals.
• When checking the wire harness, perform
steps (1) to (3).
• As a quick remedy, use a contact revitalizer
available at most part stores.
5. Check:
• Resistance
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
BASIC SERVICE INFORMATION
TIP
The resistance values shown were obtained at
the standard measuring temperature of 20 °C
(68 °F). If the measuring temperature is not 20
°C (68 °F), the specified measuring conditions
will be shown.
Coolant temperature sensor re-
sistance
5166–6314 Ω@0 °C (5166–6314
Ω@32 °F)
Coolant temperature sensor re-
sistance
288-352 Ω@80 °C (288-352
Ω@176 °F)