User Group Windows; Delivery Schedule; Monthly Auditor's Schedule - Bosch D9412GV3 Program Entry Manual

Table of Contents

Advertisement

D9412GV3/D7412GV3 | Program Entry Guide | 4.0
Table 36: Delivery Schedule*
W#
Day of Week
3
S M T W T F S
Program at least
one day Yes.
*
Monday and Wednesday, In between 2:45 AM and 3:00 AM. Out between 3:15 AM and 3:30 AM.
Another alternative for delivery schedules is to automatically bypass specific points using skeds.
Table 37: Monthly Auditor's Schedule*
W#
Day of Week
4
S M T W T F S
All days must be
programmed No.
*
Sunday, In between 8:00 AM and 8:30 AM. Out between 2:30 PM and 5:00 PM..
4.1.2

User Group Windows

In this section, you can create up to eight User Group
periods where the passcodes for the group chosen is
enabled. One user group can have multiple windows
assigned to it over a 24-hour period. Refer to the
U### User Group prompt in Section 2.1 Passcode or
Token Worksheet to assign individuals to a group.
When you assign a U### User Group to one of the
eight windows, all passcodes for the group are
enabled ONLY for the period between the Enable
Time and Disable Time for assigned User Windows
#.
If a user is not assigned to a U### User Group or
the number programmed for the user for U### User
Group is not assigned to a User Windows #, the
passcode for that user is enabled all the time.
User Group Windows do not affect the
users token or card access authority. To
enable/disable tokens, the Sked Function
Access Levels On/Off must be used.
Bosch Security Systems, Inc. | 10/11 | F01U170807-02
Open
Early
Begin
Start
Stop
02 : 30
02 : 45
03 : 00
Day(s) of the week, but not on holidays
Open
Early
Begin
Start
Stop
07 : 00
08 : 00
08 : 30
Only on holidays
Get other manuals https://www.bkmanuals.com
Schedules (Skeds)
Close
eXcept
Early
Begin
Start
Stop
Holiday
03 : 05
03: 15
03: 30
Yes
00 : 00
01 : 00
Yes
Yes
Close
eXcept
Early
Begin
Start
Stop
Holiday
14 : 00
14: 30
17: 00
Yes
No
User Windows #
Default:
1
Selection:
1 to 8
Enter the User Windows number you want to
program.
UW# User Group
Default:
1
Selection:
0 to 8
Enter the number programmed for the group of users
in the U### User Group prompt. This group has its
user passcodes enabled or disabled when this
window runs.
A User Group can be assigned to more
than one window in a 24-hour period, but
the windows must not overlap or exceed
the midnight boundary.
EN | 112
On
Holiday
Index
Area(s)
No
1 2 3 4
1 2 3 4 5 6 7 8
No
1 2 3 4
1 2 3 4 5 6 7 8
Select at
Program at least
least one
one area Yes.
index
On
Holiday
Index
Area(s)
No
1 2 3 4
1 2 3 4 5 6 7 8
Select at
Program at least
least one
one area Yes.
index

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412gv3