FireplaceXtrordinair ProBuilder 72 Linear Installation Manual page 69

Table of Contents

Advertisement

72 ProBuilder – Fireplace Preparation
1. Prepare the fireplace for installation into the framing by removing the two shields from the top of the header
standoff assembly. Remove the standoffs from the shields. Set the shields, standoffs and fasteners aside for
reinstallation.
2. Remove the header standoff assembly from the top of the fireplace by removing the (12) ¼" screws securing it
to the unit. Discard the assembly.
3. Install the two shields directly to the top of the fireplace. The upward slanted portion of the shield faces the
back of the fireplace.
Remove and discard
4. Bend up the "V" shaped standoffs and attach them to the top of the shields.
© Travis Industries
Installation
(for qualified installers only)
Standoff
Shield
Attach shields to top of fireplace,
angled portion facing backward
4/21/20 - 1458
PB 72 MV/GSB2/GSR2 Install
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

MvProbuilder 72 linear gsb2Probuilder 72 linear gsr2

Table of Contents