Table 27: L## Secure Door-Door Mode Definitions; L## Unlock Door; L## Secure Door; L## Access Ctl Lvl - Bosch D9412G Program Entry Manual

Table of Contents

Advertisement

D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN

L## Unlock Door

Default:
See
Program Record Sheet
Selection:
Blank or E
Unlock Door (MENU FUNCTION only)
Press the command center number keys [1] through
[8] that correspond to the door number to
unlock/relock doors. For example, pressing [2] and
[ENTER] unlocks door number 2, which is indicated
by U in the display.
Unlock Door allows the user with this authority level
to access the UNLOCK? 12345678 function.

L## Secure Door

Program Record Sheet
Default:
See
Selection:
Blank or E
Secure Door (MENU FUNCTION only)
Press the command center number keys [1] through
[8] that correspond to the door number to
secure/unsecure doors. For example, pressing [2]
and [ENTER] secures door number 2, which is
indicated by an X in the display.
Secure Door allows the user with this authority level
to access the SECURE? 12345678 function.
Bosch Security Systems | 10/03 | 47775E
Table 27: L## Secure Door-Door Mode
Definitions
Door State
Definition
Lock Door
Normal Door: When a door is in the
Lock Door state, one can initiate the
door sequence using Skeds, CYCLE
DOOR?, command center functions,
door requests, and valid token/card
requests.
Secure Door
No Access Allowed: When a door is
in the Secure Door state, no access
is allowed through the door until it is
returned to the Lock Door state. This
includes Sked and command center
functions.
Unlock Door
Free Access: When a door is in the
Unlocked Door state, the door is
already shunted and the strike does
not prevent the door from opening. In
this state, the user does not need to
activate a door request or present a
valid token/card.
Cycle Door
Momentary Access: This is a
temporary Door Mode in which the
door initiates the door sequence as if
a valid token/card was read. This
state occurs using the command
center and RAM. A sked cannot
activate this state.

L## Access Ctl Lvl

Program Record Sheet
Default:
See
Selection:
Blank or E
#37 Access Control Levels (MENU FUNCTION
only)
Changing the Access Control Level in any
area affects all users and all doors
associated with that level for all areas.
Access Level Ctl allows the user with this authority
level to enable/disable access control levels for all
doors activated in the control panel regardless of the
area in which the doors are assigned.