Enhanced Communications; Enable Ext Modem; Answer Armed; Answer Disarmed - Bosch D9412G Program Entry Manual

Table of Contents

Advertisement

D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1

Enable Ext Modem

Default:
No
Selection:
Yes or No
Yes
Enable SDI Address 88 for use with an
external modem.
No
Disable SDI Address 88 for use with an
external modem.
Setting this item to Yes instructs the control panel
that SDI Address 88 is enabled for use with an
external modem. For further information on Local
RPS programming, see the RPS Operation Manual.
Setting this item to Yes disables
Enhanced Communication and SDI RAM
for use over a LAN or WAN.

Answer Armed

Default:
7
Selection:
0 to 15
0
No answer when all areas are Master
Armed.
0 to 15
The control panel answers the phone
after the specified number of rings
when all areas are Master Armed.
Determines the number of rings after which the
external modem automatically answers a call if all
areas are Master Armed.

Answer Disarmed

Default:
7
Selection:
0 to 15
0
No answer when any area is Perimeter
Armed or Disarmed.
0 to 15
The control panel answers the phone
after the specified number of rings
when any area is Perimeter Armed or
Disarmed.
Determines the number of rings after which the
external modem automatically answers a call if any
area is Perimeter Armed or Disarmed.
Bosch Security Systems | 10/03 | 47775E

RAM Line Monitor

Default:
No
Selection:
Yes or No
This item is not yet implemented. Keep this item set
to No.

Seize Relay

Default:
No
Selection:
Yes or No
This item is not yet implemented. Keep this item set
to No.

Modem Init String

Default:
ATE0
Selection:
A to Z (capital letters only), 0 to 9,
[SPACE], ! " # $ % & ' ( ) * + , - . / : ;
< = > ? @ [ \ ] ^ _
Determines which initialization string the control
panel sends to the external modem when the control
panel powers up.
0101
If special characters are required, this
0101
item can only be programmed
0101
successfully from RPS. The D5200
Programmer only allows the characters
shown in the Modem Init String
default/selections.

RAM Dial String

Default:
ATDT
Selection:
Not available
This item is not yet implemented.
6.5

Enhanced Communications

Enhanced communications is the ability to
communicate by some other means than the
standard digital dialer. In this section, programmable
parameters allow you to define up to four separate
enhanced communication paths to which events can
be routed. To route an event (such as an Alarm or
Trouble) to an enhanced communication path,
additional programming must also be completed in
Section 2.3 Routing and Section 2.4 Enhanced Routing.
EN | 122

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412g

Table of Contents