Generally speaking, residential systems have less
complex access requirements. Residents will usually
be given an access code that allows them access to
their dwelling only, with no time restriction. Separate
access codes will therefore be created for each block
or landing, depending on where the readers are
located.
Other non-residents will probably need access, for
instance, deliveries, cleaners, maintenance etc. either
24 hours a day, or at restricted times.
4.2.3

How to Create Access Codes

To create access codes for a group of people you
should follow these steps:
1. Decide which doors the group will be allowed
through.
2. Decide at what times they will have access
through these doors. If necessary you can have
two lists of doors (access levels) in one access
code, one allowing access on one Time Profile,
the second allowing access at a different Time
Profile.
3. Check to see if you already have appropriate
access levels and time profiles already set up. If
not, create new ones (The A, PR and T
commands).
4.2.4
Access Levels – The AL Command
Very simply, an access level is a list of doors. There
is a maximum of 16 doors that may be controlled by
the Readykey K2200 system. You use an access level
to define which of those 16 doors different people, or
groups of people, will be allowed to use.
There are 128 possible access levels that you can set
up.
Note:
In a new system, you should find that access level 1 has
been automatically set to all doors. That is, an access
code which contains access level 1 will allow the
keyholder through all the doors in the system.
Before you attempt to use this command, you should be
aware of the numbers assigned to each door. In the
example above for instance, door 1 is the front door,
door 3 is the sales office (from reception), door 11 is the
sales office from the corridor, door 4 and door 12 are
exit doors.
The table to the right shows which doors are associated
with which door controller.
Bosch Security Systems | 7/03 | 17376 v1.1 / 47491C
Key Administration/ Access Control

Table 10: Door to Door Controller Association

Door
Controller
Master
Slave 2*
Slave 3*
Slave 4*
* Not available on Readykey K1200
In order to show all the settings for 16 doors in each
access level, the display has to be split into two
halves. You should use the [NXT] and [-] keys to
move between the two displays
To create or alter an access level
1. Present an editor key to the faceplate reader.
2. Enter the password and press [ENT], if required.
3. You will now see the CMD prompt.
4. Type [A][L] and press [ENT].
CMD AL_
5. What you see displayed are the first 8 doors of
access level 1. The 1 in the center of the display
indicates this is the first half of the display (doors
1-8).
L 1
Press [NXT] to see the second set of 8 doors.
6. The 2 indicates this is the second set of 8 doors
(9-16). In this example, access level 1 allows
access through all the possible doors in the
system.
L 1
Use the up and down arrow keys to select the
access level you want to change.
7. Once you have selected the access level you
want to change, you select or deselect doors by
typing the numbers 1-8. If a door is selected, its
number will appear on the list; if it is deselected,
a dash (-) will replace the number.
L 17 1 12----78
Press [ENT] to save any changes you have made.
Press [NXT] to see the second set of 8 doors (9-
16). Press [ENT] again to save any changes you
have made to the second set.
L 17 2 ----56--
The example shows an access level (number 17)
that allows keyholders through doors 1, 2, 7, 8,
13 and 14
8. Select another access level to change or press
[ESC] to return to the CMD prompt.
Door Numbers
1
2
3*
5
6
7*
9
10
11*
13
14
15*
1 12345678
2 12345678
EN | 22
4*
8*
12*
16*