Wiring

Wiring examples are provided in the following illustrations for the option boards.
 Wiring the PG-A2
Wiring examples are provided in the following illustrations for the PG-A2.
PG power
supply
+12 V
Short for
open-col-
lector
input
Pulse
input
-42
2
Inverter
Three-phase, 200
VAC (400 VAC)
R/L1
S/L2
T/L3
Fig 2.23 Wiring a 12 V Voltage Input
Three-phase,
Inverter
200 VAC (400 VAC)
R/L1
U/T1
S/L2
V/T2
T/L3
W/T3
4CN
Shielded twisted-pair wires must be used for signal lines.
Do not use the pulse generator's power supply for anything other than the pulse generator (encoder).
Using it for another purpose can cause malfunctions due to noise.
The length of the pulse generator's wiring must not be more than 100 meters.
Fig 2.24 Wiring an Open-collector Input
Fig 2.25 I/O Circuit Configuration of the PG-A2
U/T1
V/T2
W/T3
PC-A2
+12 V power supply
1
0 V power supply
2
4CN
4CN
3
4
12 V voltage input (A/B phase)
TA1
5
Pulse 0 V
6
E
E
7
TA2 (E)
8
PG-A2
+12 V power supply
1
0 V power supply
2
4CN
3
4
TA1
Pulse input (+)
5
Pulse input (-)
6
E
E
7
TA2 (E)
8
Pulse monitor output
(Short circuit across
terminals 3-4)
Pulse monitor output
Pulse input
Pulse
monitor
output

Hide quick links: