Starting Torque Compensation - YASKAWA Varispeed G7 Series Instruction Manual

General purpose inverter (advanced vector control)
Hide thumbs Also See for Varispeed G7 Series:
Table of Contents

Advertisement

Normally, there is no need to make this setting. Adjust the constant as shown below.
If the motor is vibrating, increase the set value.
If the motor response is low, decrease the set value.

Starting Torque Compensation

Starting torque compensation can be input during open-loop vector control to increase the torque reference
even faster when starting the motor.
Starting torque compensation is effective when starting torque is required for machines with a high frictional
load and cranes. However, starting torque compensation differs from flux vector control in that compensation
is provided only when starting the motor.
Related Constants
Constant
Number
C4-03
C4-04
C4-05
Master speed reference
Forward (reverse) run
command (S1 (S2))
Time constant: C4-05
Torque compensation
Output frequency
When using this function, set the starting torque compensation amount to the frictional load for a normal
machine or to the load for an elevating machine, such as a crane.
Frictional load: Set both C4-03 and C4-4 to the amount of friction.
-40
6
Name
Description
Display
Forward start-
Sets the forward start-
ing torque
ing torque as a percent-
age of the motor rated
F TorqCmp@
torque.
start
Reverse start-
Sets the reverse starting
ing torque
torque as a percentage
of the motor rated
R TorqCmp@
torque.
start
Sets the delay time in
Starting torque
ms for the starting
time constant
torque.
The filter is disabled if
TorqCmp
the time is set to 0 to 4
Delay T
ms.
(A1)
Open
Time constant:
C4-02
amount
C4−05 × 4
E1−09
Note
The above torque compensation amount lower limit is applied to the Inverter's torque reference value.
Fig 6.34 Starting Torque Compensation Timing Chart
Change
Fac-
Setting
during
tory
Range
Opera-
V/f
Setting
tion
0.0 to
0.0%
×
200.0
-200.0
0.0%
×
to 0.0
0 to
10 ms
×
200
Closed
C4-03 (forward)
C4-03 (forward)
C4-03 (forward)
C4-04 (reverse, negative polarity)
C4-04 (reverse, negative polarity)
C4-04 (reverse, negative polarity)
Control Methods
V/f
Open-
Open-
Flux
with
Loop
Loop
Vector
PG
Vector 1
Vector 2
×
×
A
×
×
×
×
A
×
×
×
×
A
×
×
Larger of b2-01 and E1-09
MEMO-
BUS
Page
Regis-
ter
217H
218H
219H

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents