YASKAWA Varispeed G7 Series Instruction Manual page 528

General purpose inverter (advanced vector control)
Hide thumbs Also See for Varispeed G7 Series:
Table of Contents

Advertisement

No.
Low-speed regeneration stability
N4-30
coefficient 2
Speed estimator gain fluctuation
N4-32
frequency 1
Speed estimator gain fluctuation
N4-33
frequency 2
Speed estimator gain fluctuation
N4-34
rate
N5-01
Feed forward control selection
N5-02
Motor acceleration time
N5-03
Feed forward proportional gain
o1-01
Monitor selection
o1-02
Monitor selection after power up
Frequency units of reference set-
o1-03
ting and monitor
Setting unit for frequency con-
o1-04
stants related to V/f characteristics
o1-05
LCD brightness adjustment
LOCAL/REMOTE key enable/dis-
o2-01
able
STOP key during control circuit
o2-02
terminal operation
o2-03
User constant initial value
o2-04
kVA selection
Frequency reference setting
o2-05
method selection
Operation selection when digital
o2-06
operator is disconnected
* 1. Not initialized. (Japanese standard specifications: A1-00 = 1, A1-02 = 2)
* 2. The factory setting will change when A1-02 (Control Method) is changed. The factory settings of the open-loop vector 1 control are given.
* 3. The factory setting is 1.0 when using flux vector control.
* 4. The factory setting is 2.00 s when Inverter capacity is 55 kW min.
The factory setting will change when the control method is changed. The open-loop vector 1 factory setting is given.
* 5. By setting E2-11 (Motor rated output) the appropriate value will be set.
* 6. The factory settings depend on the Inverter capacity. The values for a 200 V Class Inverter of 0.4 kW are given.
* 7. When the control method is changed, the factory settings will change. The flux vector factory settings are given.
* 8. This constant can be monitored or set only when F is set for C6-02.
* 9. These are values for a 200 V Class Inverter. Values for a 400 V Class Inverter are double.
* 10.E1-11 and E1-12 are disregarded when set to 0.0.
* 11.E1-13 is set to the same value as E1-05 by autotuning.
* 12.The same capacity as that of the Inverter will be set if the constants are initialized.
* 13.Applicable for G7-Series Inverters with software versions PRG 1038 and later. Refer to MECHATROLINK COMMUNICATIONS INTERFACE CARD INSTRUC-
TIONS (TOBPC73060008) for details.
* 14.The factory settings in the parentheses are for 3-wire sequence.
-40
10
Table 10.9 User Constants (Continued)
Fac-
Name
tory
Setting
1.00
5.0
20.0
200.0
*7
0
*6
0.178
1.0
6
1
0
0
3
1
1
0
*6
0
0
0
Set-
No.
ting
o2-07
Cumulative operation time setting
Cumulative operation time selec-
o2-08
tion
o2-10
Fan operation time setting
Fault trace/fault history clear func-
o2-12
tion
Output power monitor clear selec-
o2-14
tion
*18
Capacitor maintenance setting
o2-18
o3-01
Copy function selection
o3-02
Read permitted selection
T1-00
Motor 1/2 selection
T1-01
Autotuning mode selection
T1-02
Motor output power
T1-03
Motor rated voltage
T1-04
Motor rated current
T1-05
Motor base frequency
T1-06
Number of motor poles
T1-07
Motor base speed
Number of PG pulses when turn-
T1-08
ing
*18
Motor no-load current
T1-09
Fac-
Name
tory
Setting
0
0
0
0
0
0
0
0
1
*2
0
*6
0.40
*9
200.0
*6
1.90
60.0
4
1750
600
*6
1.20
Set-
ting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents