Stopping the Inverter by Notifying Programming Device Errors to the
Inverter (External Fault Function)
The external fault function performs the error contact output, and stops the Inverter operation if the Inverter
peripheral devices break down or an error occurs. The digital operator will display EFx (External fault [input
terminal Sx]). The x in EFx shows the terminal number of the terminal that input the external fault signal. For
example, if an external fault signal is input to terminal S3, EF3 will be displayed.
To use the external fault function, set one of the values 20 to 2F in one of the constants H1-01 to H1-10 (multi-
function contact input terminal S3 to S12 function selection).
Select the value to be set in H1-01 to H1-10 from a combination of any of the following three conditions.
Signal input level from peripheral devices
External fault detection method
Operation during external fault detection
The following table shows the relationship between the combinations of conditions and the set value in H1-
.
Set
Value
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
Note 1. Set the input level to detect errors using either signal ON or signal OFF. (NO contact: External fault when ON; NC contact: External fault when
OFF).
2. Set the detection method to detect errors using either constant detection or detection during operation.
Constant detection: Detects while power is supplied to the Inverter.
Detection during operation: Detects only during Inverter operation.
-86
6
Input Level
Error Detection Method
(See Note 1.)
NO Con-
NC Con-
Constant
tact
tact
Detection
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
(See Note 2.)
Detection
Deceler-
During
ate to Stop
Operation
(Error)
Yes
No
Yes
Yes
No
Yes
No
Yes
Yes
No
Yes
Yes
Yes
No
No
Yes
No
No
No
Yes
No
No
Yes
No
Yes
No
No
Yes
No
No
No
Yes
No
No
Yes
No
Yes
No
No
Yes
No
No
No
Yes
No
No
Yes
No
Operation During Error Detection
Coast to
Emer-
Stop
gency Stop
(Error)
(Error)
No
No
No
No
No
No
No
No
Yes
No
Yes
No
Yes
No
Yes
No
No
Yes
No
Yes
No
Yes
No
Yes
No
No
No
No
No
No
No
No
Continue
Operation
(Warning)
No
No
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes