Wiring Example
This example shows wiring for conforming to undervoltage reference.
Fuse
R
3-phase power
200 to 240 V
S
50/60 Hz
T
Vm
2MCCB THRX
OFF
Thermal relay trip contact
for Braking Resistor Unit
1
2
Thermal relay trip contact
for motor cooling fan
1
2
MC
MC
MA
External
frequency
references
* 1. The main circuit is separated from the terminal cover for safety reasons.
* 2. The contact output circuit is separated from the main circuit and the control circuit by reinforced insulation.
It can be connected to extra-low voltage circuits or circuits that are 250 VAC 1 A, 30 VDC 1 A or less.
* 3. The control circuit is an extra-low voltage circuit and separated from the main circuit and the contact output circuit by reinforced insulation. Always
connect it to extra-low voltage circuits.
-14
10
2MCCB
FU
FV
FW
Noise
filter
1MCCB
MC
ON
MC
Forward Run/Stop
MC
SA
THRX
Reverse Run/Stop
Thermal switch contact
SA
for Braking Unit
3
4
External fault
Fault reset
TRX
SA
Multi-step speed reference 1
(Main speed switching)
TRX
reference 2
Fault contact
Multi-step speed
Jog frequency
selection
External
Multi-function
baseblock command
contact inputs
Multi-step speed
Factory
reference 3
settings
Multi-step speed
reference 4
Acc/dec time 1
Emergency stop
(NO)
Pulse train input
Frequency setting
2kΩ
adjustment
Frequency
setter
3
0 to +10V
2kΩ
2
1
P
4 to 20mA
P
0 to +10V
MEMOBUS
communications
RS-485/422
Thermal switch
contact
Braking Unit
3
(optional)
+
Level
detector
-
+ 1
+ 3
Inverter
R/L1
S/L2
CIMR-G7A2018
T/L3
PG-B2
S1
(optional)
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
+24V 8mA
CN5 (NPN setting)
SC
+24V
Shield wire
E (G)
connection
terminal
Master speed
RP
pulse train
0 to 32 kHz (3 kΩ)
High level: 3.5 to 13.2 V input
Frequency setting power
+V
+15 V, 20 mA
A1
Master speed reference
0 to 10 V (20 kΩ)
Master speed reference
A2
4 to 20 mA (250 Ω)
[0 to 10 V (20 k Ω ) input]
Multi-function anlog input
A3
0 to 10 V (20 kΩ)
P
AC
Factory setting:
0V
Not used
-V
( -15V 20mA)
Terminating
resistance
R+
R-
S+
S-
IG
Fig 10.6
Thermal relay
trip contact
4
1
2
+
P
0
-
B
0
Braking Resistor Unit
(optional)
FU
* 1
FV
-
FW
U
U/T1
V
V/T2
W
W/T3
TA1
1
C
2
H
3
B
4
G
5
A
6
F
TA3
D
Shielded twisted-pair
wires
TA2
1
Pulse monitor output
Pulse A
30 mA max.
2
3
Pulse B
Wiring distance:
d
4
30 m max.
MP
Pulse train output
0 to 32 kHz (2.2 k Ω )
AC
Default: Output
frequency
Ammeter adjustment
AM
20k Ω
Multi-function analog output 2
-10 to 10 V 2 mA
-
+
Default: Output current
AM
0 to +10 V
Ammeter adjustment
FM
20k Ω
Multi-function analog output 1
-10 to 10 V 2 mA
AC
-
+
FM
Default: Output frequency
0 to +10 V
E(G)
* 2
MA
MA
Error contact output
MB
250 VAC, 10 mA min. 1 A max.
MC
30 VDC, 10 mA min. 1 A max.
MC
M1
Multi-function contact output
M2
250 VAC, 10 mA min. 1 A max.
30 VDC, 10 mA min. 1 A max.
Default: Running
signal
P1
Open collector 1
Default: Zero-
speed
Multi-function
open-collector outputs
P2
48 VDC 50 mA max.
Open collector 2
Default: Frequency
PC
agree signal
P3
Open collector 3
Factory setting:
C3
Inverter operation
ready
P4
Open collector 4
Factory setting:
C4
minor fault
* 3
Motor
Cooling fan
IM
IM
PG