Stopping the Inverter by Notifying Programming Device Errors to the
Inverter (External Fault Function)
The external fault function performs the error contact output, and stops the Inverter operation if the Inverter
peripheral devices break down or an error occurs. The digital operator will display EFx (External fault [input
terminal Sx]). The x in EFx shows the terminal number of the terminal that input the external fault signal. For
example, if an external fault signal is input to terminal S3, EF3 will be displayed.
To use the external fault function, set one of the values 20 to 2F in one of the constants H1-01 to H1-10 (multi-
function contact input terminal S3 to S12 function selection).
Select the value to be set in H1-01 to H1-10 from a combination of any of the following three conditions.
Signal input level from peripheral devices
External fault detection method
Operation during external fault detection
The following table shows the relationship between the combinations of conditions and the set value in H1-
.
Input Level
(See Note 1.)
Set
Value
NO Con-
NC Con-
tact
20
Yes
21
22
Yes
23
24
Yes
25
26
Yes
27
28
Yes
29
2A
Yes
2B
2C
Yes
2D
2E
Yes
2F
Note 1. Set the input level to detect errors using either signal ON or signal OFF. (NO contact: External fault when ON; NC contact: External fault when
OFF).
2. Set the detection method to detect errors using either constant detection or detection during operation.
Constant detection: Detects while power is supplied to the Inverter.
Detection during operation: Detects only during Inverter operation.
Error Detection Method
(See Note 2.)
Detection
Constant
During
tact
Detection
Operation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Input Terminal Functions
Operation During Error Detection
Deceler-
Coast to
Emer-
ate to Stop
Stop
gency Stop
(Error)
(Error)
(Error)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Continue
Operation
(Warning)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
85