Replacing Consumables and Maintenance Kit
K K K K
Match (U U U U ) on the front of the Fus-
er Oil Unit and the arrow on the
Fusing Unit as shown in the illus-
tration.
Important
❒ Be careful not to get oil on the
5
metal point of the left side of the
Fuser Oil Unit.
L L L L
Insert the left and right protru-
sions of the Fuser Oil Unit into
the white holders of the Fusing
Unit (A A A A ), and then move the Fus-
er Oil Unit in the direction shown
by the arrow (B B B B ) to attach the Fus-
er Oil Unit to the Fusing Unit.
70
M M M M
Holding the green handle with
one hand, use your other hand to
push the front area of the handle
to create a slight slant, and push
the Fusing Unit slowly to the
back.
ZDJH055J
Note
❒ Confirm that the Fuser Oil Unit
is facing the inside of the print-
er.
At this point, make sure the Fusing
Unit is on the stand properly.
N N N N
Close the upper left cover (A A A A ) and
push the handle slowly (B B B B ) to the
back until it clicks into place.
ZDJH054J
O O O O
Place the old Fuser Oil Unit into
the bag which contained the new
Fuser Oil Unit, and seal the bag.
ZDJH050E
ZDJH051J