Software Update - Graco PR-Xv Instructions Manual

Variable ratio metering system
Table of Contents

Advertisement

Software update

SD card (2000359) is applied to update the software, or
change the system from I/O communication mode to
Profinet communication mode.
Insert the SD card in the indicated slot to complete
software update. If necessary, set the IP address after
software update.
NOTE: Do not remove the SD card once it is inserted
into the control box, because the control box can not
work without the SD card.
Insert the SD card
1. Turn off the control box power.
2. Open the cover of the SD card inserting position.
3. Insert the SD card.
F
. 55 Insert the SD Card
IG
Change the IP address
After inserting the SD card or establishing Profinet
communication mode, the data on the screen may be
displayed as ####.
In this case, it is necessary to edit communication
connections and make sure the network settings for
Insert the SD card here
Profinet mode are in the subnet with HMI and PLC IP
address.
For operation instructions, see Edit communication
connections, page 45, and Edit network settings,
page 47.
Edit communication connections
1. Start PR-Xv control box and push 'Settings' on the
'Start Center' screen.
2. Select 'Service & Commissioning' on the 'Settings'
screen.
3. Select 'Assign PLC Address' from the 'Service &
Commissioning' list, then touch the cycle in the
middle of screen to see complete information.
Operation
45

Advertisement

Table of Contents
loading

Table of Contents