Shut Down - Graco PR-Xv Instructions Manual

Variable ratio metering system
Table of Contents

Advertisement

Operation
3. Edit IP address directly from the 'Network Interface'
screen.
4. Return to the 'Start Center' main screen and restart
HMI.
48

Shut down

This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow Pressure Relief
Procedure.
To avoid injury from toxic fluids or fumes, such as
splashing in the eyes or on skin, wear appropriate
personal protective equipment.
Standard shutdown
1. Make sure the system finishes the current job. The
dispense valve closes after a job.
2. Remove Static Mixer Package (AA, page 8) from TC
Dispense Valve (AB, page 8).
F
. 56 Remove Static Mixer Package
IG
3. Place a waste container below the TC Dispense
Valve (AB, page 8) and activate a small shot to flush
the mixed material out of the valve.
4. Perform the Pressure Relief Procedure, page 50.