Appendix A - Error Number Message - Graco PR-Xv Instructions Manual

Variable ratio metering system
Table of Contents

Advertisement

Appendix A - Error number message

Appendix A - Error number message
Error
Error
Error Name Description
No.
Type
0
----
No Error
1
Error
E-stop
2
Error
Part A
reaches the
lower limit
3
Error
Part A
reaches the
higher limit
4
Error
Part B
reaches the
lower limit
5
Error
Part B
reaches the
higher limit
6
Error
Part A servo
alarm
7
Error
Part B servo
alarm
8
Error
Part A
pre-charge
time out
9
Error
Part B
pre-charge
time out
10
Error
Part A high
pressure
alarm
11
Error
Part B high
pressure
alarm
12
Error
Purge alarm
13
Error
System
power off
14
Error
Home
request
60
Cause
System emergency
System Emergency Stop Switch
, page 9
stops
(BC
Moving of metering
1. Improper position of limit sensor
cylinder A touches
2. Damage of limit sensor
the lower limit sensor
3. Drive mechanism error
Moving of metering
cylinder A touches
4. Interference around limit sensor
the higher limit
sensor
Moving of metering
cylinder B touches
the lower limit sensor
Moving of metering
cylinder B touches
the higher limit
sensor
Servo fault
Servo system error
Pre-charge time
1. Target pre-charge pressure is
exceeds the set
set too high or pe-charge speed is
maximum time
set too low
2. Insufficient material in metering
cylinder
Pressure exceeds the
1. Pressure sensor error
system limit
2. Maximum working pressure is
set too low
3. Dispense outlet line clogged
4. Dispense rate is too fast
5. Dispense Valve (AB
not open
6. Material inlet line error
Purge is not executed
Auto purge is open and Pot life
within Pot life
time is over
System power off
Power supply is disconnected
The operator needs
Home is not executed after system
to execute home
power on
Solution
Make sure the system is in safety
status. Plug Emergency Stop
) is pressed
Switch (BC
Control Power On button (BB
page 9
close the alarm.
Note: Execute Home after system
emergency stop.
1. Re-install lower limit sensor
2. Replace lower limit sensor
3. Repair drive mechanism
4. Check limit sensor
1. Check servo drive alarm code
and trouble shoot per the alarm
code
2. Restart the control box
1. Set proper pre-charge
parameters
2. Check the material supply line
and execute reload
1. Replace pressure sensor
2. Set proper maximum working
pressure
3. Clean dispense outlet line
4. Set proper dispense rate
, page 8
5. Check dispense solenoid valve
) is
6. Check inlet line and replace
damaged parts
1. Go to Manual Main Screen, and
execute manual purge
2. Execute home
Check power connection lines and
power-on buttons
Press Home icon to execute home
, page 9
), press
,
), and press reset icon to

Advertisement

Table of Contents
loading