IO signals

Signal
NO.
Signal Name
Style
1
INPUT
CUST_IN_DISPENSE
2
CUST_IN_PURGE
3
CUST_IN_RELOAD
4
CUST_IN_STYLEBIT_0
5
CUST_IN_STYLEBIT_2
6
CUST_IN_ESTOP
7
CUST_IN_REMOTE_RST
8
CUST_IN_MODE_SELECT
9
CUST_IN_STYLEBIT_1
10
CUST_IN_JOB_START
11
CUST_IN_STYLEBIT_3
12
CUST_IN_COMMON
13
OUTPUT CUST_OUT_READY
14
CUST_OUT_COMPLETE
15
CUST_OUT_INRELOAD
16
CUST_OUT_ALARM
17
CUST_OUT_ERR_BIT0
18
CUST_OUT_ERR_BIT1
19
CUST_OUT_ERR_BIT2
20
CUST_OUT_ERR_BIT3
21
CUST_OUT_ERR_BIT4
22
CUST_OUT_INCYCLE
23
CUST_OUT_PURGE_REQUEST
24
CUST_OUT_RELOAD_REQUEST Q3.3
25
CUST_OUT_INJOB
26
CUST_OUT_STANDBY
27
CUST_OUT_COMMON
88
Pin
PLC
Description
number
address
I2.0
X20
used to start dispensing in bead mode
or shot mode
I2.1
X21
used to start purge.
I2.2
X22
used to start reloading material.
I2.3
X23
BIT0-3: 0-15, for select style
I2.4
X24
I3.0
X30
used to connect customer emergency
stop button
I3.1
X31
used to reset error
I2.5
X25
used to set working mode in automatic
0 means shot mode
1 means bead mode
I3.3
X33
I3.2
X32
used to start job, normal
I3.4
X34
P24
Q2.0
31
Q2.1
32
Q2.2
33
Q2.3
34
Q2.4
35
please check error code
Q2.5
36
Q2.6
37
Q2.7
38
Q3.0
39
Q3.1
40
Q3.2
41
42
Q3.4
43
Q3.5
44
30