Profinet Map - Graco PR-Xv Instructions Manual

Variable ratio metering system
Table of Contents

Advertisement

Profinet map

Control box input from PLC output
Name
GATE_IN_CMD_BITS
GATE_IN_NOTUSED
GATE_IN_STYLE_NO
Control box output to PLC input
Name
GATE_OUT_STATUS_0
GATE_OUT_STATUS_1
GATE_OUT_ERR_CODE
GATE_OUT_DISP_VOL
GATE_OUT_JOB_VOL
GATE_OUT_DISP_RATE
GATE_OUT_PRESS_A
GATE_OUT_PRESS_B
GATE_OUT_MTR_TRQ-A
GATE_OUT_MTR_TRQ-B
GATE_OUT_DISP_RATIO
Units
0
JOB_START
1
DISPENSE
2
RELOAD
3
PURGE
4
REMOTE_RESET
5
MODE_SELECT
6
SYS_RELIEF
7
SUPPLY_STOP
Units
0 READY
1 INDISPENSE
2 COMPLETED
3 INRELOAD
4 PURGE_REQUEST
5 RELOAD_REQUEST
6 ALARM
7 STANDBY
0 INJOB
1 INPURGE
2
3
4
5
6 INPURGE
In Byte Description
1
used to start job, normal
used to start dispensing in bead mode or shot mode
used to start reloading material
used to purge response
used to reset error
used to set working mode in automatic
0 means shot mode
1 means bead mode
used to open dispense valve and relief pressure in
metering system
used to stop cartridge material supply
2
not used
3-4
0-15, for select style
In Byte Description
1
2
HEARBEAT
3-4
5-6
Integer, should multiply by 0.1, unit is CC
7-8
Integer, should multiply by 0.1, unit is CC
9-10
Integer, should multiply by 0.1, unit is CC
11-12
Integer, unit is PSI
13-14
Integer, unit is PSI
15-16
Integer, should multiply by 0.001, unit is N•m
17-18
Integer, should multiply by 0.001, unit is N•m
19-20
Integer, should multiply by 0.1
Schematics
89