Repair

Repair Token Cable

1. Perform the Pressure Relief Procedure, page 14.
2. Disconnect the unit from the power source.
3. Remove all 12 screws (20) and washers from
the electronics cover (50). See F
4. Carefully tilt the electronics cover (50) down.
See F
. 31, page 28.
IG
All wires must be disconnected before the cover is
completely removed. Hold the cover in place while dis-
connecting wires or let the cover rest on a work sur-
face to avoid damaging the wires and connections.
5. Check the token wire (T) connections. Replace the
wire if it is damaged.
NOTE: Make sure the token wire connection is posi-
tioned with the wires facing the bottom of the driver (as
seen below).
F
. 37: Token Wire
IG
6. Install the cover and tighten all 12 screws (20) and
washers. Torque to 15-20 ft-lb (20-27 N•m).
If wires get pinched when the cover screws are tight-
ened, damage will occur. Make sure all wires are posi-
tioned inside the cover before installation.
7. Connect the power cord.
30
. 30, page 28.
IG
NOTICE
T
NOTICE

Software Update Procedure

1. Perform the Pressure Relief Procedure, page 14.
2. Disconnect the unit from the power source.
3. Remove the two screws (53) and washers. Then
remove the junction box cover (BA) from the driver
to gain access to the token slot (TS).
BA
53
F
. 38: Token Slot Location
IG
4. Insert and press the token firmly into the slot.
NOTE: The token has no preferred orientation.
5. Tuck the wires back into the junction box (BC) and
reinstall the junction box cover (BA) with two screws
and washers.
If wires get pinched when the cover screws are tight-
ened, damage will occur. Make sure all wires are posi-
tioned inside the cover before installation.
6. Connect the unit to the power source and turn it ON.
7. The red indicator light (L) will flash while the soft-
ware is being loaded (approximately 30 seconds).
When the software is completely loaded, the red
light will turn off for four seconds before the software
version flashes. Then a solid light will stay on.
NOTICE