Pot life: When the system completes jobs, the
control box counts down from the set 'Pot life'.
When it counts down to '0', the system activates
the alarm of purging.
Idle period: When the system completes jobs, the
control box counts down from the set 'Idle Period'.
When the time counts down to '0', purge fails.
Purge shot size: set the total volume of purge.
Note: 'Idle period' restores to the set value after purge.
If purge fails, the operator need to replace the mixing
tube (if the materials are solidified), reset the alarm, and
perform manual purge.
The automatic purge flow is as follows:
Auto Purge
Enabled
Count down
in the set
'Pot life' after
jobs
Countdown is
over, the system
sends out
purging request
Confirm if it is at
the purge
position
Move to the
Yes
purge position
Purge at the
Send out
current
purge request
dispense rate
Purge the set
'Purge shot
size' volume
Purge
completed
No
No actions until
countdown
ends in the set
' Idle Period'
Purge failed
HMI Display Operation and Identification
Base purge setup
1. When executing base purge, select the base purge
object of part A or part B.
-
Green color indicates the selected. Meanwhile,
the selected part is showed on the Manual
Main Screen.
2. Set rate in 'Base Purge rate' and volume in 'Base
Purge Volume'.
3. In Manual Main Screen, select the
execute base purge.
-
Dispense is disabled after base purge, but the
reload is available.
-
The operator needs to conduct manual purging
after flushing, and confirm whether the base
purge medium has been drained from the
mixing tube.