Gas Connection; Electrical Connection; Pressure Testing - Rangemaster Professional 110 Dual Fuel Users Manual & Installation

Installation instructions
Hide thumbs Also See for Professional 110 Dual Fuel:
Table of Contents

Advertisement

Gas Connection

The gas supply needs to terminate with a down facing
bayonet. The rear cover boxes limit the position of the
supply point.
view from the rear
A
position for gas supply connector
B
appliance gas inlet
Because the height of the cooker can be adjusted and
each connection is different it is difficult to give precise
dimensions. Ideally the house supply bayonet should
be in the shaded area shown in the diagram. Although
a 900mm hose can be used, a 1250mm hose will allow
slightly more flexibility in the positioning of the bayonet
and make moving the cooker easier. The hose should
be fitted so that both inlet and outlet connections are
vertical so that the hose hangs downwards.
The connector is located just below the hotplate level
at the rear of the cooker.
For Natural Gas the flexible hose must be in
accordance with B.S.669.
For LP Gas it should be capable of 50mbar
pressure, 70°C temperature rise and carry a red
stripe, band or label.
If in doubt contact, your supplier. Screw connect the
threaded end of the hose into the gas inlet in the
underside of the connector block on the back of the
cooker.
After completing the gas connection, check the cooker
is gas sound with a pressure test.

Pressure testing

The gas pressure can be measured at one of the LH
hotplate burner injectors. Lift off a burner head. Fit the
pressure gauge to the injector. Turn on the hotplate
burner and turn on and light one of the other hotplate
burners.
Pressure
For Natural Gas 20mbar.
For LP Gas 29mbar for Butane, 37mbar for Propane.
Reassemble burner top, making sure it is reassembled
in the correct way on the burner body.

Electrical Connection

This appliance must be installed by a qualified
electrician to comply with the relevant Institute of
Electrical Engineers (I.E.E.) regulations and also
the local electricity supply company requirements.
WARNING: THIS APPLIANCE MUST BE EARTHED
Note
The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker,
through a suitable cooker control unit incorporating a
double pole switch having a contact separation of at
least 3mm in all poles. This cooker must not be
connected to an ordinary domestic power point.
The cable size used should be between 6mm
2
10mm
, twin and earth.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel.
Connect the mains cable to the correct terminals for
your electrical supply type (see fig.). Check that the
links are correctly fitted and that the terminal screws
are tight. Secure the mains cable using the cable
clamp.
These appliances are of type X with regard to
protection against over heating of the surrounding
surfaces.
Current Operated Earth Leakage
Breakers
Where the installation is protected by a 30 milliamp
sensitivity residual current device (RCD), the combined
use of your cooker and other domestic appliances may
occasionally cause nuisance tripping. In these
instances the cooker circuit may need to be protected
by fitting 100mA device. This work should be carried
out by a qualified electrician.
27
2
and

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents