Technical Data - Rangemaster Professional 110 Dual Fuel Users Manual & Installation

Installation instructions
Hide thumbs Also See for Professional 110 Dual Fuel:
Table of Contents

Advertisement

Technical Data

This cooker is category II
It is supplied set for either:-
A conversion kit from NG to LP gas is available.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION:
Country of Destination: GB/IE
Gas
Natural Gas
Butane
Propane
(See appliance data badge for test pressures)
Dimensions
Overall height
Overall width
Overall depth
Space for fixing
Minimum space above hotplate
Connections
Gas:
Rp
1
/
at rear right-hand side
2
Ratings
Hotplate
Wok burner
Large Burner
Medium Burners
Small Burner
Gas burner inputs based on Gross Calorific Value
Ovens
Conventional Oven
Grill
Warmer
Maximum total electrical load at 230V 7.2kW*
*approximate total including oven lights, oven fan etc.
2H3+
a) group H natural gas or b) LP gas.
Cooker back, serial number repeater badge below oven door opening.
Electric
20mbar
220 - 240V 50Hz
29mbar
37mbar
minimum 893mm maximum 920mm
1100mm
648mm
See 'Positioning of Cooker'
650mm
220 - 240V 50Hz
Natural Gas
3.5kW internal 80
3.0kW 134
1.7kW 109
1.0kW 75
Oven
Browning Element
2.2kW
2.3kW
160W
See 'Positioning of Cooker'
Electric
L.P. Gas
Injector
3.5kW (246g/h) internal 54
external 129
3.0kW (210g/h) 87
1.7kW (119g/h) 68
1.0kW (70g/h)
Fan Oven
1.15kW
2.5kW
30
Injector
external 77
51