Electrical Connection

This appliance must be installed by a qualified
electrician to comply with the relevant regulations and
also the local electricity supply company requirements.
Make sure that the mains characteristics (voltage, nominal,
power, etc.) match the ratings indicated on the data plate
affixed to the lower right hand cooker upright (remove
storage drawer). The cooker is preset for a single-phase
earthed electrical connection. It is essential to install a
multi-pole circuit breaker that completely disconnects the
appliance from the mains, with a minimum contact break
distance of 3mm.
WARNING: THIS APPLIANCE MUST BE EARTHED
The appliance must be connected to an efficient earthing
circuit. If the electricity network is not equipped with an
earth connection, then it must be installed separately in
compliance with local regulations. Earthing is a safety
measure required by law, and must be performed with
particular care by a qualified technician, who must also
check that the electricity supply characteristics are correct.
The cable size used should be suitable for the appliance
load and in accordance with local regulations. Please note
the maximum cable sizes are 6mm
and 10mm
for the 3 pronged links.
2
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect
the mains cable to the correct terminals for your electrical
supply type (see fig.).
Check that the links are correctly fitted and that
the terminal screws are tight.
Secure the mains cable using the cable clamp.
for the screw terminals
2
27
This shows the single-phase connection.
Current Operated Earth Leakage
Breakers
Where the installation is protected by a 30 milliamp
sensitivity residual current device (RCD), the combined
use of your cooker and other domestic appliances may
occasionally cause nuisance tripping. In these instances the
cooker circuit may need to be protected by fitting 100mA
device. This work should be carried out by a qualified
electrician.

Fitting the plinth

Fit the inner plinth to the bottom front of the cooker
using the 5 screws provided.
Fit the outer plinth (2 screws 1 each end) to the inner
plinth. The height of the outer plinth can be adjusted by
sliding it up or down via the slotted hole.
Oven Light
Press the oven light switch and check that the light is
working.
NB The oven light bulb is not included in the guarantee
Hobplate
Turn on each plate in turn and check that it heats up.
Grill
Open the grill compartment door. Turn on the grill control
and check that the grill heats up.