Unit Shuts Down in 15‐20 
minutes with an "FS" code on 
control board. (Failed Start) 
  
  
"OT" Code on Control Board 
(OverTemp) 
 
 
Notes: 
  
 
1. Whenever instructed to check/replace the vacuum sensor, also check for loose or cracked vacuum hose.  
Also, be certain the vacuum measurement port in the firebox is kept clean (clean with a pipe cleaner or 
brush, do not use a vacuum to clean this port). 
  
 
2. To restart and clear an error code displayed on the control board, push the "ON" button and the unit 
should reset the error and restart. 
  
3. If you are uncertain about the meaning of an error code or have any questions at all, PLEASE contact 
Technical Support at (800)245‐6489. 
 
 
 
 
 
IMPORTANT!  READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND 
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR 
 
 
 
1. Loose thermal sensor. 
2. Control board settings. 
3. Failure to light pellets. 
1. Convection (Room Air) blower failure. 
2. Partially blocked flue. 
3. Using fuel other than premium wood 
pellets. 
  
 
 
 
 
REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED. 
USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS. 
 
1. Check both sides of thermal sensor 
connection (exhaust blower and 
control board). 
2. Start stove on minimum Heat 
Range 5 to ensure a good fire is 
started. 
3. Check igniter for buildup or failure. 
1. Check convection blower for 
proper function, replace if necessary. 
2. Check flue for obstructions. 
3. Use ONLY premium wood pellets 
in this stove. 
  
  
  
  