England's Stove Works 55-TRPCB120 Installation & Operation Manual page 12

Hide thumbs Also See for 55-TRPCB120:
Table of Contents

Advertisement

 
INSTALLATION 
Approved Venting Method 2: Through the Ceiling 
 
 Seal each pipe connection joint with high temperature RTV Silicone, to ensure the system is leak 
free (Check with the specific pipe manufacturer's instructions before doing so). 
 If the pellet vent pipe being used is not a "Twist Lock" system, three (3) sheet metal screws are 
required at each pipe joint. 
 Connect the pellet stove to outside combustion air using the kit included with your stove or using 
an alternative method, as described in the "Outside Air" section, on page 15. 
 This venting method can also be modified so that the venting system runs horizontally through the 
wall from the stove, then transitions to vertical and terminates above the roofline.  When using 
this modified version of this installation be certain to carefully follow the venting system 
manufacturer's instructions diligently. 
 
Please Note: 
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each 
individual installation.  Please follow all venting system requirements, maintain the required clearances to combustibles, and 
follow all local codes. 
 
IMPORTANT!  READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND 
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR 
 
 
 Venting through the ceiling/roof may be the only feasible 
venting option in some cases and is a factory recommended 
installation. 
 When installing any venting system, Type L or Type PL pipe 
must be used and all clearances to combustibles listed by the 
pipe manufacturer must be strictly adhered to. 
 Use the pipe manufacturer's approved ceiling support for 
passing through a combustible ceiling, as well as the required 
fire stops, radiation shields, flashing and storm collar. 
 Be certain to follow the manufacturer's required height of 
termination above the roof line, and maintain at least the 
minimum clearances to combustibles. 
 Use an appliance collar where the pellet vent connects to the 
exhaust output of the pellet stove and attach the appliance 
collar to the exhaust blower output using three sheet metal 
screws.  
 
REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED. 
USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS. 
For high altitude installations 
(above 4,000 ft.), the vent pipe 
should be increased from 3‐inch 
(3") to four‐inch (4"). 