 After approximately fifteen minutes, the fire should be burning brightly.  At this point, the stove has begun 
normal operation and the display windows on the control board will display your setting, unless the board 
is adjusted. 
 It is normal for the unit to smoke during the first fire, as paints and oils cure.  This should dissipate within 
the first hour.   Open a door and/or window during the first fire to ventilate the area. 
  
Daily Operation Notes 
 Only high quality, Premium Grade ¼" (.25 in.) diameter wood pellets should be used in this stove.  
Using low grade wood pellets with high ash content OR  wood pellets with a high moisture content 
can cause the burn pot to fill with ash at a more rapid pace and can cause intervals between 
periodic maintenance to become significantly shorter.  Please read the "Maintenance" section of 
this manual thoroughly to understand how fuel selection affects stove operation, maintenance 
and cleaning. 
 Variation in the flame height is normal; not all wood pellet fuel is uniform in size, which can affect 
the way pellets are fed into the burn pot.  Although the flame height may increase and decrease 
during operation, there is no loss of efficiency. 
 Always store wood pellet fuel in a dry location; storing wood pellet fuel in a dry location ensures 
the fuel will remain pelletized and low in moisture content.  Also, be certain that all wood pellet 
fuel is stored at a safe distance from the pellet heater; storing fuel in close proximity to the stove 
can result in a fire.  Do not install or operate this unit outside, in a greenhouse, or in any area 
that is high in moisture. 
 This pellet burning room heater is equipped with a specially designed burn pot which comes 
preinstalled from the factory.  This burn pot elevates the burning pellets and delivers air at the 
precisely‐required locations.  Pellets must only be burned in the factory burn pot; no modifications 
should be made to this burn pot and no additional grates or other fire elevators should be used. 
 
 The circuit board is equipped with "Reminder Messages" which will pop up and scroll on the 
display at various times. 
 
 As noted above, the control board will ask the user if they have cleaned out the burn pot prior to 
every start with "HOLD ON TO CONFIRM". 
 
 "Daily cleaning reminder" ‐ After the unit has run for 46 consecutive hours of burn time, the board 
will display a reminder to shut the unit down and perform daily cleaning with "PLEASE SHUT 
DOWN AND CLEAN BURN POT". This reminder code does NOT shut the unit down, but WILL scroll 
until the unit is completely shut down by the user. Control of the stove is not affected by the 
IMPORTANT!  READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND 
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR 
 
 
REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED. 
USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS. 