 The use of outside combustion air is mandatory on this pellet stove. 
 The outside air connection pipe protrudes from the lower rear center of the 
stove; use the included outside air kit to attach your stove to outside 
combustion air.  Instructions and all the parts needed to make the outside air 
connection to your pellet stove are included with the outside air kit. 
 If it is not feasible to use the included outside air hookup kit in your stove 
installation, other materials may be used, provided the following rules are 
followed: 
 The pipe used for outside air hookup must be metal, with a minimum 
thickness of .0209 in. (25 gauge mild steel) or greater and an inside 
diameter of approximately 2.0 in. 
 All pipe joints and connections should be sealed with pipe clamps or other 
mechanical means, to insure a leak free outside air connection. 
 Long runs of pipe and excessive elbows for outside air should be avoided.  
Due to frictional resistance in pipe, any excessive outside air piping can 
result in poor stove performance. 
 A screen or other protection device must be fitted over the outside air 
termination point to prevent rain, debris and nuisance animals from 
entering the piping system. 
 Increase the outside air pipe size to 3.0 in. diameter pipe if the outside air 
connection is more than 6 ft. in length, more than two (2) elbows are used 
or if the stove is installed in a basement. 
 The outside air connection system should be inspected at least annually to be 
certain it is free from blockage. 
 
IMPORTANT!  READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND 
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR 
 
 
OUTSIDE AIR HOOK‐UP 
NEVER draw outside combustion air from: 
1. Wall, floor or ceiling cavity. 
2. Enclosed space such as an attic, garage or crawl space. 
REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED. 
USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS. 
Caution 
16 

Advertisement

Table of Contents
loading

This manual is also suitable for:

55-shpcb12025-cb12025-ssp01

Table of Contents