England's Stove Works 55-TRPCB120 Installation & Operation Manual page 23

Hide thumbs Also See for 55-TRPCB120:
Table of Contents

Advertisement

"FAILED ON VACUUM LOSS SHUTTING DOWN".  The unit will then initiate a shutdown cycle, 
and the message will continue to scroll during this time until the unit shuts completely off. 
During this shutdown,  the stove cannot be restarted; if the "ON" button is pressed during 
shutdown the unit will scroll "STOVE MUST SHUT DOWN TO CLEAR ERROR" once, before 
reverting to the previous message. 
 
 Once the unit has shut down completely the control board will scroll "FAILED ON VACUUM 
LOSS". At this point the stove can be restarted in its normal sequence by pressing the "ON" 
button, or the code can be cleared by pressing the "OFF" button. 
 
 
Hopper Left Open 
 This unit is also equipped with a hopper lid safety switch that is actuated by a tab which is 
part of the hopper lid. The switch is a required safety device, which prevents the auger 
from cycling when the lid is open. An error message is triggered if the lid is left open for 60 
continuous seconds ‐ if this occurs, the control board will scroll "HOPPER LEFT OPEN 
SHUTTING DOWN".  The unit will then initiate a shutdown cycle, and the message will 
continue to scroll during this time until the unit shuts completely off. During this shutdown,  
the stove cannot be restarted; if the "ON" button is pressed during shutdown the unit will 
scroll "STOVE MUST SHUT DOWN TO CLEAR ERROR" once, before reverting to the previous 
message. 
 
Once the unit has shut down completely the control board will scroll "HOPPER LEFT OPEN". 
At this point the stove can be restarted in its normal sequence by pressing the "ON" button, 
or the code can be cleared by pressing the "OFF" button.
If an error code continues to display, if the error code seems unexplainable, or if you have 
any other questions about error codes and what they mean, please contact Technical 
 
 
 
 
 
 
 
 
 
 
IMPORTANT!  READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND 
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR 
 
 
Support at (800) 245‐6489. 
 
REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED. 
USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS. 