Obtaining a Power Cord Set

WARNING
Do not attempt to modify or use an AC power cord that is not the exact
type required.
Because a power cord is not supplied for the server, you must obtain a power cord that meets the
following criteria:
For North America the cord must be UL Listed/CSA Certified, 14/3, 75 °C type SJT with
NEMA 6-15P attachment plug and IEC 320, C19 outlet.
For outside North America the cord must be flexible VDE certified or <HAR> (harmonized)
rated 250 V, 0.75 mm
than the product ratings. The attachment plug shall be a three conductor grounding type, rated
125% of the total input current rating of the product and must be for the configuration in the
specific region or country. The attachment plug must bear at least an accepted safety agency
certification mark for the specific region or country.
The cord must be no longer than 4.5 meters (14.76 ft).

Turning on Your Server

WARNING
The push-button on/off power switch on the front panel of the server
does not turn off the AC power. To remove AC power from the server,
you must unplug the power cord from the AC inlet filter or wall outlet.
1. Make sure all external devices, such as a video monitor, keyboard, and mouse (optional) have
been connected.
2. Remove drive protection cards (if present) from the removable media drives.
3. Turn on your video monitor.
4. Plug the female end of the power cord into the AC inlet filter receptacle on the back of the
chassis.
5. Plug the male end of the power cord into a properly grounded power outlet. See page 29 for
power outlet requirements.
6. If the server does not come on when you plug the power cord into the power outlet, press the
power switch on the front panel.
7. Verify that the power-on light on the front panel is lit. After a few seconds the power-on self
test (POST) begins. See "Power-on Self Test" on page 35.