Intel AC450NX Product Manual page 97

Rack server system
Hide thumbs Also See for AC450NX:
Table of Contents

Advertisement

AC450NX Rack Server System Product Guide
Updating DMI Nonvolatile Storage Area
After programming the BMC FRU area, the utility then programs the following Chassis, Board,
and Product FRU information to the DMI fields.
Example:
Loading DMI System Area
Manufacturer Name : Intel
Name : AC450NX Server System
Version Number : ASDK128M1P2MBPP
Serial Number : 0123456789
Loading DMI Board Area
Manufacturing Name : Intel
Name : AC450NX Server System
Serial Number : 0123456789
Version Number : 661880-303
Loading DMI Chassis Area
Chassis Part Number : 693792-003
Chassis Serial Number : Z00418630
Asset Tag :
If a failure occurs, the utility displays an error message and exits.
Updating the SDR Nonvolatile Storage Area
After the utility validates the header area of the supplied SDR file, it updates the SDR repository
area. Before programming, the utility clears the SDR repository area. The utility filters all tagged
SDRs depending on the product configuration set in the configuration file. Nontagged SDRs are
automatically programmed. The utility also copies all written SDRs to the SDR.TMP file; it
contains an image of what was loaded. The TMP file is also useful for debugging the server.
Cleaning Up and Exiting
If an update was successfully performed, the utility displays a single message and then exits.
If the utility fails, it immediately exits with an error message and exit code.
96