Front Panel Controller (FPC)
Where located: on the front panel board
What it manages:
server power control consolidation from several sources
 push-button power signal from the front panel connector
 real-time clock (RTC)
 server monitor module (SMM), if installed
 commands from the Intelligent Platform Management Bus (IPMB)
power and reset switch interfaces
fault LEDs
chassis, midplane and power supplies Field Replacement Unit (FRU) inventory interface
server hard reset generation
server power fault indication
Intelligent Chassis Management Bus (ICMB) bridge device
EMP connection
LCD interface
Board Management Controller (BMC)
Where located: on the PHP I/O baseboard
What it provides:
temperature and voltage monitoring of the I/O and CPU baseboards
threshold comparison functions
SMI (systems management interrupt) generation
watchdog timer and certain GPIO (general purpose input/output) functions
fault-resilient booting
processor presence, Voltage ID (VID), IERR, and thermal trip monitoring
server event log, event time stamping, sensor data record information, and DIMM ID
information interface
current event status and sensor readings when polled by System Management Software
Hot-swap Controller (HSC)
Where located: on the disk backplane
What it does:
implements the SAF-TE command set
controls the fault lights and drive power-on
provides a path for management information via SCSI
retrieves drive fault status, backplane temperature, and fan failure information via the IPMB
queries the status of the front panel controller for power supply information
controls drive power-on and power-down, facilitating hot-swapping
Chapter 17 PHP I/O Baseboard: Description/Setting Configuration Jumpers