AC450NX Rack Server System
This guide explains how to boot your server from the Server Configuration Software CD. After
booting the server from the CD, you can create software installation diskettes, run PC diagnostics
on the server, and read and/or print the online Product Guide.
WARNING
To avoid personal injury when unpacking the server, use only a
mechanical assist unit to lift it off the shipping pallet.
The minimum server configuration weighs about 51.4 kg (113 lbs), and
the maximum one weighs close to 60 kg (132 lbs). Do not attempt to lift
or move the server by the handles on the power supplies.
Contents
Select a site.......................................................................................................................... 3
After unpacking the server.................................................................................................... 4
Installing the server .............................................................................................................. 4
Connect keyboard, mouse, and monitor, and printer ............................................................ 8
Obtain a power cord ............................................................................................................. 9
Turn on video monitor and server......................................................................................... 9
Power-on self test............................................................................................................... 11
Boot from the server configuration software CD ................................................................. 11
Access the server Product Guide ....................................................................................... 12
Using the Acrobat .PDF files...................................................................................... 12
Copy server configuration software to diskettes ................................................................. 13
If server won't boot from the CD......................................................................................... 13
WARNING: English (US) ................................................................................................... 15
AVERTISSEMENT: Français............................................................................................. 17
WARNUNG: Deutsch ........................................................................................................ 19
AVVERTENZA: Italiano ..................................................................................................... 21
ADVERTENCIAS: Español................................................................................................ 23
Quick Start Guide
for the
Order Number: 718699-004
AC450NX Rack Server System 1

Advertisement

Table of Contents
loading

Summary of Contents for Intel AC450NX

  • Page 1: Table Of Contents

    Copy server configuration software to diskettes ..............13 If server won’t boot from the CD..................13 WARNING: English (US) ....................15 AVERTISSEMENT: Français..................... 17 WARNUNG: Deutsch ......................19 AVVERTENZA: Italiano ..................... 21 ADVERTENCIAS: Español....................23 AC450NX Rack Server System 1...
  • Page 2 Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice.
  • Page 3: Select A Site

    NEMA 6-15R outlet for 200-240 V~. NOTE For 100-120 V~ operation see the Power System chapter in the AC450NX Rack Server System Product Guide.  For international sites, this means a grounded power outlet applicable for the electrical code of the region.
  • Page 4: After Unpacking The Server

    After unpacking the server Inspect the shipping box for evidence of mishandling during transit. If the shipping box is damaged, photograph it for reference. After removing the contents, keep the damaged box and the packing materials. If the contents appear damaged, file a damage claim with the carrier immediately.
  • Page 5 (113 lbs), and the maximum one weighs close to 60 kg (132 lbs). To avoid injury, we recommend that a lift be used to insert the server into the slide assemblies in the equipment rack. AC450NX Rack Server System 5...
  • Page 6 1. Select a height within the rack to install the slide assemblies. 2. Using the screws and nuts provides, attach the slide assemblies on the rack. OM07362 Slide assembly front Slide assembly rear 3. Fully extend the slide assemblies until they lock into place. 4.
  • Page 7 OM07363 Slide assembly tabs System tab slots 6. Unlock the slide assemblies by pressing outward on each locking tab and push the system into the rack. OM07364 AC450NX Rack Server System 7...
  • Page 8: Connect Keyboard, Mouse, And Monitor, And Printer

    Connect keyboard, mouse, and monitor, and printer Keyboard † Connect the signal cable of a PS/2 -compatible keyboard to the keyboard port on the server I/O panel. Mouse Connect the signal cable of a PS/2-compatible mouse to the mouse port on the server I/O panel. Monitor †...
  • Page 9: Obtain A Power Cord

    7. Verify that the power-on light on the front panel is lit. After a few seconds the power-on self test (POST) begins. See “Power-on self test” on page 11. AC450NX Rack Server System 9...
  • Page 10 D E F G K J I OM07301 Power switch Reset switch C. NMI switch D. Power LED (green) Power fault LED (yellow) Cooling fault LED (yellow) G. Drive fault LED (yellow) H. Front panel LCD Drive fault LED (yellow) Drive activity LED (green) Drive power LED (green) Open/close button...
  • Page 11: Power-On Self Test

    Handle the CD only by the inner and outer edges. Do not touch the data side of the CD—the side without the label. 3. Gently grasp the center hole and outer edge of the CD, remove it from the case, and place it label-side up in the tray. AC450NX Rack Server System 11...
  • Page 12: Access The Server Product Guide

    4. Press the open/close button or gently push on the tray—it will automatically slide into the drive. OM06774 Open/close push-button switch CD tray 5. Press the reset switch on the front panel to reboot the server. 6. When POST completes, the server beeps once, boots from the CD, installs a mouse driver, and displays the CD-ROM menu bar.
  • Page 13: Copy Server Configuration Software To Diskettes

    To override the boot sequence, do this: 1. Press the reset switch on the front panel to reboot the server—the CD can be in the drive or not. 2. When POST displays this message: Press <F2> to enter SETUP AC450NX Rack Server System 13...
  • Page 14 3. Press <Esc> and wait for the following boot menu to display: OM08360 4. From the boot menu, select the CD-ROM drive, and press <Enter>. 5. When you see the following pop-up menu, press <Enter> to boot from the CD. OM08361 The server should now boot from the CD, displaying a menu bar that includes creating diskettes, diagnostics, reading/printing the manual, and quitting to DOS.
  • Page 15: Warning: English (Us)

    Check that cables, add-in boards, and other components are properly installed. Attach the covers to the chassis with the screws removed earlier, and tighten them firmly. Connect all external cables and the AC power cord(s) to the system. continued AC450NX Rack Server System 15...
  • Page 16 WARNING: English (continued) A microprocessor and heat sink may be hot if the system has been running. Also, there may be sharp pins and edges on some board and chassis parts. Contact should be made with care. Consider wearing protective gloves. Danger of explosion if the battery is incorrectly replaced.
  • Page 17: Avertissement: Français

    Assurez-vous que les câbles, les cartes d’extension et les autres composants sont bien installés. Revissez solidement les panneaux du boîtier avec les vis retirées plus tôt. Rebranchez tous les cordons d’alimentation c. a. et câbles externes au système. suite AC450NX Rack Server System 17...
  • Page 18 AVERTISSEMENT: Français (suite) Le microprocesseur et le dissipateur de chaleur peuvent être chauds si le système a été sous tension. Faites également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l'usage de gants de protection. Danger d'explosion si la batterie n'est pas remontée correctement.
  • Page 19: Warnung: Deutsch

    Bringen Sie die Abdeckungen wieder am Gehäuse an, indem Sie die zuvor gelösten Schrauben wieder anbringen. Ziehen Sie diese gut an. Schließen Sie alle externen Kabel und den AC Stromanschlußstecker Ihres Systems wieder an. Fortsetzung AC450NX Rack Server System 19...
  • Page 20 WARNUNG: Deutsch (Fortsetzung) Der Mikroprozessor und der Kühler sind möglicherweise erhitzt, wenn das System in Betrieb ist. Außerdem können einige Platinen und Gehäuseteile scharfe Spitzen und Kanten aufweisen. Arbeiten an Platinen und Gehäuse sollten vorsichtig ausgeführt werden. Sie sollten Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr.
  • Page 21: Avvertenza: Italiano

    Controllare che i cavi, dei supporti aggiuntivi ed altri componenti siano stati installati appropriatamente. Attaccare le coperture al telaio con le viti tolte in precedenza e avvitarle strettamente. Ricollegare tutti i cavi esterni e le prolunghe AC del sistema. continua AC450NX Rack Server System 21...
  • Page 22 AVVERTENZA: Italiano (continua) Se il sistema è stato a lungo in funzione, il microprocessore e il dissipatore di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. Esiste il pericolo di un esplosione se la pila non viene sostituita in modo corretto.
  • Page 23: Advertencias: Español

    Inserte el bloqueo de seguridad en el sistema y bloquéelo para impedir que pueda accederse al mismo sin autorización. Conecte todos los cables externos y los cables de alimentación CA al sistema. continúa AC450NX Rack Server System 23...
  • Page 24 ADVERTENCIAS: Español (continúa) Si el sistema ha estado en funcionamiento, el microprocesador y el disipador de calor pueden estar aún calientes. También conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes. Por ello, se recomienda precaución y el uso de guantes protectores.