Removing Dimms - Intel AC450NX Product Manual

Rack server system
Hide thumbs Also See for AC450NX:
Table of Contents

Advertisement

AC450NX Rack Server System Product Guide

Removing DIMMs

See Figure 19-7.
1. Observe the precautions on page 115, "Safety Guidelines."
2. Remove the top and side covers as described in Chapter 12, "Server Covers:
Removing/Reinstalling."
3. Remove the memory module as described in Chapter 13, "Server Components:
Removing/Reinstalling."
4. Starting with the first DIMM-filled socket closest to the top edge of the module, remove the
DIMMs one at a time.
CAUTION
Use extreme care when removing a DIMM. Too much pressure can damage
the socket slot. Apply only enough pressure on the plastic ejector levers to
release the DIMM.
5. Gently push the plastic ejector levers out and down to eject the DIMM from the socket
(Figure 19-7).
6. Carefully lift the DIMM away from the socket, and store it in an antistatic package.
7. Repeat the above steps to remove other DIMMs.
8. Reinstall the memory module as described in Chapter 13.
9. Reinstall the top and side covers as described in Chapter 12.
10. Reconnect all external cables and the power cords to the server.
11. Turn on your monitor and then your server.
12. Run the SSU to configure the server and to properly attribute ECC memory. Failure to do so
may degrade the performance of your server. For information about running the SSU, see
Chapter 5, "System Setup Utility: When to Run."
242
Figure 19-7. Removing DIMMs
OM06768

Advertisement

Table of Contents
loading

Table of Contents