Inreceivefromhmi - Siemens SIMOCRANE Operating Instructions Manual

Energy storage system management v01.01
Table of Contents

Advertisement

Name
MaxDischargingPower
MaxChargingPower
NominalFullPack
RemainingNominalFullPack
UsableFullPack
RemainingUsableFullPack
ChargeTotal
DischargeTotal
ChargeCycles
DischargeCycles
Table 5-23
inReceiveFromMaster.BMS.Battery.Module1 – Module8
Input
inReceiveFromMaster.BMS.Bat‐
tery.Module1 – Module8
Table 5-24
inReceiveFromMaster.BMS.Battery.Module1 – Module8
Name
Cell_Temp_Min
Cell_Temp_Max
Cell_Temp_Avrg
Cell_Voltage_Min
Cell_Voltage_Max
Cell_Voltage_Avrg
ModuleSNr
Warning
Fault
5.1.4

inReceiveFromHMI

The structure of the block input "inReceiveFromHMI" is identical to that of the input
"inReceiveFromMaster". No BMS or watchdog information is transferred from the HMI however.
For more details, see "inReceiveFromMaster (Page 40)".
SIMOCRANE Energy Storage System Management V01.01
Operating Instructions, 04/2023, A5E51573536B AE
Data type
Unit
Real
kW
Real
kW
Real
kWh
Real
kWh
Real
kWh
Real
kWh
Real
kWh
Real
kWh
Real
-
Real
-
Name
Data
type
Module1 – Mod‐
LTypes_B
ule8
MS_Bat‐
tery_Mo
dule
Data type
Unit
Real
°C
Real
°C
Real
°C
Real
V
Real
V
Real
V
Double word
-
Bool
-
Bool
-
Comment
Highest measured discharging power
Highest measured charging power
Maximum total battery capacity
Remaining total battery capacity
Maximum usable battery capacity
Remaining usable battery capacity
Total charge energy
Total discharge energy
Number of charge cycles
Number of discharge cycles
Higher-level data
Comment
type
BMS
-
Comment
Minimum measured cell temperature
Maximum measured cell temperature
Average measured cell temperature
Minimum measured cell voltage
Maximum measured cell voltage
Average measured cell voltage
Number of battery module
Warning in battery system
Fault in battery system
Block interface