Diagnostic system
7.3 Faults
Bit 5
Message class
Component
Response
Acknowledgement
Cause
Remedy
Bits 6-31
-
7.3.7

Unit 2

Bit 0
Message class
Component
Response
Acknowledgement
Cause
Remedy
Bit 1
Message class
Component
Response
Acknowledgement
Cause
Remedy
Bit 2
Message class
Component
Response
Acknowledgement
Cause
Remedy
128
Unit Disconnected while running
Fault
Internal SIMOCRANE ESSM Vx.x
Shutdown routine 3
ETechAcknowledge
Unit 1 was disconnected from the line supply during operation
Fuse tripped
Clarify the cause
Replace the fuse links if necessary
Spare
-
Unit CAT-0 Stop
Fault
Internal SIMOCRANE ESSM Vx.x
Shutdown routine 3
ETechAcknowledge
Unit 2 has triggered an internal CAT-0 stop
Clarify the cause (see following messages)
Unit Fault present
Fault
Internal SIMOCRANE ESSM Vx.x
Shutdown routine 3
ETechAcknowledge
Unit 2 has an internal fault
Clarify the cause (see following messages)
Unit Communication Fault
Fault
Internal SIMOCRANE ESSM Vx.x
Shutdown routine 3
ETechAcknowledge
The communication connection to the unit is faulted
Check the network connection
SIMOCRANE Energy Storage System Management V01.01
Operating Instructions, 04/2023, A5E51573536B AE