Additional Zone - Daikin EBVZ-D9W Installer's Reference Manual

Table of Contents

Advertisement

11.6.4 Additional zone

ERLA11~16D + EBVZ16S18+23D
Daikin Altherma 3 R F
4P643604-1B – 2022.05
INFORMATION
The setting [F‑0B] is only valid when there is a thermostat or external room
thermostat request setting (NOT in case of leaving water temperature setting).
During cooling: If [F‑0B] is enabled, the shut off valve closes when the unit is
running in cooling operation mode. Enable this setting to avoid cold leaving water
through the heat emitter and the forming of condensation (e.g. under floor heating
loops or radiators).
#
Code
[2.D.2]
[F-0C]
WD curve type
The weather-dependent curve can be defined using the 2-points method or the
Slope-Offset method.
See
"11.5.2 2-points
curve" [
#
Code
[2.E]
N/A
Overview
The following items are listed in the submenu:
3
Room
Main zone

Additional zone

Space heating/cooling
Tank
Setpoint screen
Control the leaving water temperature for the additional zone via setpoint screen
[3] Additional zone.
See
"11.3.5 Setpoint
screen" [
The shut off valve:
0 No: is NOT influenced by changing the space
operation mode to cooling.
1 Yes: closes when the space operation mode
is cooling.
4
 153] and
"11.5.3 Slope-offset
2-points
Slope-Offset
[3] Additional zone
Setpoint screen
[3.1] Schedule
[3.2] Heating schedule
[3.3] Cooling schedule
[3.4] Setpoint mode
[3.5] Heating WD curve
[3.6] Cooling WD curve
[3.7] Emitter type
[3.8] Setpoint range
[3.9] Control
[3.A] Ext thermostat type
[3.B] Delta T
[3.C] WD curve type
4
 141].
11
Configuration
|
Description
4
curve" [
 154].
Description
Installer reference guide
173

Advertisement

Table of Contents
loading

Table of Contents