Daikin EBVZ-D9W Installer's Reference Manual page 289

Table of Contents

Advertisement

Field settings table
Breadcrumb
Field code
Setting name
9.I
[C-0E]
--
9.I
[D-00]
Which heaters are permitted if prefer. kWh rate PS is cut?
9.I
[D-01]
Contact type of preferential kWh rate PS installation?
9.I
[D-02]
Which type of DHW pump is installed?
9.I
[D-03]
Leaving water temperature compensation around 0°C.
9.I
[D-04]
Is a demand PCB connected?
9.I
[D-05]
Is the pump allowed to run if prefer. kWh rate PS is cut?
9.I
[D-07]
Is a solar kit connected?
9.I
[D-08]
Is an external kWh meter used for power measurement?
9.I
[D-09]
Is an external kWh meter used for power measurement, kWh meter used for smart
grid or a gas meter for hybrid unit?
9.I
[D-0A]
--
9.I
[D-0B]
--
9.I
[D-0C]
--
9.I
[D-0D]
--
9.I
[D-0E]
--
9.I
[E-00]
Which type of unit is installed?
9.I
[E-01]
Which type of compressor is installed?
9.I
[E-02]
What is the indoor unit software type?
9.I
[E-03]
What is the number of backup heater steps?
9.I
[E-04]
Is the power saving function available on the outdoor unit?
9.I
[E-05]
Can the system prepare domestic hot water?
9.I
[E-06]
Is a DHW tank installed in the system?
9.I
[E-07]
What kind of DHW tank is installed?
9.I
[E-08]
Power saving function for outdoor unit.
9.I
[E-09]
--
9.I
[E-0A]
Tank volume
9.I
[E-0B]
Is a bizone kit installed?
9.I
[E-0C]
What bizone system type is installed?
9.I
[E-0D]
Is glycol present in the system?
9.I
[E-0E]
--
9.I
[F-00]
Pump operation allowed outside range.
9.I
[F-01]
Above which outdoor temperature is cooling allowed?
9.I
[F-02]
--
9.I
[F-03]
--
9.I
[F-04]
--
9.I
[F-05]
--
9.I
[F-06]
--
9.I
[F-07]
--
9.I
[F-08]
--
9.I
[F-09]
Pump operation during flow abnormality.
9.I
[F-0A]
--
9.I
[F-0B]
Close shut-off valve during thermo OFF?
9.I
[F-0C]
Close shut-off valve during cooling?
9.I
[F-0C]
What is the pump operation mode?
9.I
[F-0D]
What is the pump operation mode?
9.I
[F-0E]
--
(*1) *6V_(*2) *9W_
(*3) *18*_(*4) *23*_
(*5) + EKHVCONV4
Range, step
Default value
0
R/W
0: None
1: BSH only
2: BUH only
3: All heaters
R/W
0: No
1: Active open
2: Active closed
3: Smart grid
R/W
0: No DHW pump
1: Instant hot water
2: Disinfection
3: Circulation
4: Circulation and disinfection
R/W
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
R/W
0: No
1: Pwr consmp ctrl
R/W
0: Forced off
1: As normal
R/O
0: No
1: Yes
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
8: 1 pulse/m³ (gas meter)
9: 10 pulses/m³ (gas meter)
10: 100 pulses/m³ (gas meter)
R/W (*4)
0 (*4)
R/O (*3)
2 (*3)
2
0
0
0
R/O
0~5
0: LT split
R/O
1
R/W (*5)
0: Reversible (*5)
R/O
1: Heating only
R/O
3: 6V (*1)
4: 9W (*2)
R/O
0: No
1: Yes
R/O
0: No
1: Yes
R/O
0: No
1: Yes
R/O
1: Integrated
R/W
0: Disabled
1: Enabled
1
R/O
180 (*10)
230 (*11)
R/O
1: Bizone present
R/O
0: Without hydraulic separator / no
direct pump
R/O
0: No
1: Yes
0
R/W
0: Disabled
1: Enabled
R/W
10~35°C, step: 1°C
20°C
3
5
0
0
0
0
0
R/W
0: Disabled
1: Enabled
0
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0: Continuous
1: Sample
2: Request
R/W
0: Continuous
1: Sample
2: Request
20
11/12
Installer setting at variance with
default value
Date
Value
4P655202-1 - 2021.09