Piping Installation; Preparing Refrigerant Piping; Refrigerant Piping Requirements - Daikin EBVZ-D9W Installer's Reference Manual

Table of Contents

Advertisement

8
|

Piping installation

8 Piping installation
In this chapter

8.1 Preparing refrigerant piping

8.1.1 Refrigerant piping requirements

Installer reference guide
74
INFORMATION
This unit is a heating only model. Therefore, all references to cooling in this
document are NOT applicable.
8.1
Preparing refrigerant piping ...................................................................................................................................................
8.1.1
Refrigerant piping requirements ...........................................................................................................................
8.1.2
Refrigerant piping insulation..................................................................................................................................
8.2
Connecting the refrigerant piping..........................................................................................................................................
8.2.1
About connecting the refrigerant piping...............................................................................................................
8.2.2
Precautions when connecting the refrigerant piping............................................................................................
8.2.3
Guidelines when connecting the refrigerant piping..............................................................................................
8.2.4
Pipe bending guidelines .........................................................................................................................................
8.2.5
To flare the pipe end..............................................................................................................................................
8.2.6
To braze the pipe end ............................................................................................................................................
8.2.7
Using the stop valve and service port....................................................................................................................
8.2.8
To connect the refrigerant piping to the outdoor unit .........................................................................................
8.2.9
To connect the refrigerant piping to the indoor unit............................................................................................
8.3
Checking the refrigerant piping..............................................................................................................................................
8.3.1
About checking the refrigerant piping...................................................................................................................
8.3.2
Precautions when checking the refrigerant piping ...............................................................................................
8.3.3
Checking refrigerant piping: Setup ........................................................................................................................
8.3.4
To check for leaks...................................................................................................................................................
8.3.5
To perform vacuum drying ....................................................................................................................................
8.4
Charging refrigerant ...............................................................................................................................................................
8.4.1
About charging refrigerant ....................................................................................................................................
8.4.2
Precautions when charging refrigerant .................................................................................................................
8.4.3
Charging additional refrigerant..............................................................................................................................
8.4.4
Completely recharging refrigerant ........................................................................................................................
8.4.5
To fix the fluorinated greenhouse gases label.......................................................................................................
8.5
Preparing water piping ...........................................................................................................................................................
8.5.1
Water circuit requirements ...................................................................................................................................
8.5.2
Formula to calculate the expansion vessel pre-pressure......................................................................................
8.5.3
To check the water volume and flow rate.............................................................................................................
8.5.4
Changing the pre-pressure of the expansion vessel .............................................................................................
8.5.5
To check the water volume: Examples ..................................................................................................................
8.6
Connecting water piping ........................................................................................................................................................
8.6.1
About connecting the water piping .......................................................................................................................
8.6.2
Precautions when connecting the water piping....................................................................................................
8.6.3
To connect the water piping..................................................................................................................................
8.6.4
To connect the recirculation piping.......................................................................................................................
8.6.5
To fill the water circuit ........................................................................................................................................... 100
8.6.6
To fill the domestic hot water tank........................................................................................................................ 100
8.6.7
To insulate the water piping .................................................................................................................................. 100
INFORMATION
Also read the precautions and requirements in the
4
precautions" [
Also see
"7.1.4  Special requirements for R32
requirements.
Piping length: See
"7.1.3 Installation site requirements of the indoor
 10].
"2  General safety
4
units"  [
  54] for additional
unit" [
ERLA11~16D + EBVZ16S18+23D
Daikin Altherma 3 R F
4P643604-1B - 2022.05
74
74
75
75
75
76
77
77
77
78
79
80
83
83
83
84
84
84
85
86
86
87
88
88
89
90
90
93
93
96
96
97
97
97
97
99
4
 53].

Advertisement

Table of Contents
loading

Table of Contents