6.3.5 DHW pump for disinfection

6.4 Setting up the energy metering

Installer reference guide
40
You can program a schedule to control the DHW pump via the user interface. For
more information, see the user reference guide.
Setup
a
a Cold water IN
b Hot water OUT (shower (field supply))
c DHW pump (field supply)
d Heater element (field supply)
e Non‑return valve (field supply)
The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see
4
pump" [
 118].
If the applicable legislation requires a higher temperature than the maximum
tank setpoint during disinfection (see [2-03] in the field settings table), you can
connect a DHW pump and heater element as shown above.
If applicable legislation requires disinfection of the water piping until the tapping
point, you can connect a DHW pump and heater element (if needed) as shown
above.
To ensure a complete disinfection, you have to open the tapping point.
WARNING
When opening the tapping point, the water temperature can be up to 55°C.
Configuration
The indoor unit can control DHW pump operation. For more information, see
4
"11 Configuration" [
 131].
Via the user interface, you can read out the following energy data:
-
Produced heat
-
Consumed energy
You can read out the energy data:
-
For space heating
-
For space cooling
-
For domestic hot water production
b
c
d
e
"9.3.5 To connect the domestic hot water
ERLA11~16D + EBVZ16S18+23D
Daikin Altherma 3 R F
4P643604-1B – 2022.05