Daikin ERLA11D V3 Series Installer's Reference Manual page 294

Hide thumbs Also See for ERLA11D V3 Series:
Table of Contents

Advertisement

4/13
Field settings table
Breadcrumb Field code
Setting name
5.7.2
[2-00]
Operation day
5.7.3
[2-02]
Start time
5.7.4
[2-03]
Tank setpoint
5.7.5
[2-04]
Duration
Tank
5.8
[6-0E]
Maximum
5.9
[6-00]
Hysteresis
5.A
[6-08]
Hysteresis
5.B
Setpoint mode
└─ WD curve
5.C
[0-0B]
Leaving water value for high ambient temp. for DHW WD curve.
5.C
[0-0C]
Leaving water value for low ambient temp. for DHW WD curve.
5.C
[0-0D]
High ambient temp. for DHW WD curve.
5.C
[0-0E]
Low ambient temp. for DHW WD curve.
Tank
5.D
[6-01]
Margin
User settings
└─ Quiet
7.4.1
Activation
7.4.3
Level
└─ Electricity price
7.5.1
High
7.5.2
Medium
7.5.3
Low
User settings
7.6
Gas price
Installer settings
└─ Configuration wizard
└─ System
9.1.3.2
[E-03]
BUH type
9.1.3.3
[E-05]
Domestic hot water
[E-06]
[E-07]
9.1.3.4
[4-06]
Emergency
9.1.3.5
[7-02]
Number of zones
9.1.3.6
[E-0D]
Glycol filled system
9.1.3.7
[6-02]
BSH capacity (*3)
9.1.3.8
[C-02]
Bivalent
9.1.3.9
[D-07]
Solar
└─ Backup heater
4P655201-1 - 2021.09
Range, step
Default value
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
R/W
0~23 hour, step: 1 hour
1
R/W
[E-07]≠1:
55~75°C, step: 5°C
60°C
[E-07]=1:
60°C
60°C
R/W
[E-07]≠1:
5~60 min, step: 5 min
40 min
[E-07]=1:
40~60 min, step: 5 min
40 min
R/W
[E-07]=0 or 7 (*3):
40~60°C, step: 1°C
60°C
[E-07]=1 (*4):
40~65°C, step: 1°C
60°C
[E-07]=3 or 8 (*3):
40~75°C, step: 1°C
75°C
[E-07]=5 (*3):
40~80°C, step: 1°C
80°C
R/W
2~40°C, step: 1°C
8°C
R/W
2~20°C, step: 1°C
10°C
R/W
0: Fixed
1: Weather dependent
R/W
35~[6-0E]°C, step: 1°C
50°C
R/W
45~[6-0E]°C, step: 1°C
55°C
R/W
10~25°C, step: 1°C
15°C
R/W
-40~5°C, step: 1°C
-10°C
R/W
0~10°C, step: 1°C
0°C
R/W
0: OFF
1: Manual
2: Automatic
R/W
0: Quiet
1: More Quiet
2: Most Quiet
R/W
0,00~990/kWh
1/kWh
R/W
0,00~990/kWh
1/kWh
R/W
0,00~990/kWh
1/kWh
R/W
0,00~990/kWh
0,00~290/MBtu
1,0/kWh
R/O
3: 6V (*1)
4: 9W (*2)
R/W (*3)
No DHW (*3)
R/O (*4)
EKHW, small volume (*3)
Integrated (*4)
EKHW, big volume (*3)
EKHWP (*3)
3rd party, small coil (*3)
3rd party, big coil (*3)
R/W
0: Manual
1: Automatic(normal SH/DHW ON)
2: Auto red SH/DHW ON
3: Auto red SH/DHW OFF
4: SH ON/DHW OFF
R/W
0: Single zone
1: Dual zone
R/O
0: No
1: Yes
R/W
0~10kW, step: 0,2kW
3kW (*3)
0kW (*4)
R/W
0: No
1: Bivalent through header
[E-07]=5
0: No
R/W (*4)
1: Yes
(*1) *6V_(*2) *9W_(*3) EBB*_(*4) EBV*_
Installer setting at variance with
default value
Date
Value
(*5) *X*_(*6) *H*_(*7) *11*_(*8) *16*_
(*9) *SU*_(*10) *18*_(*11) *23*

Advertisement

Table of Contents
loading