8.6.2 Precautions when connecting the water piping

8.6.3 To connect the water piping

ERLA11~16D + EBVH/X11+16S18+23D
Daikin Altherma 3 R F
4P643602-1B – 2022.05
INFORMATION
Also read the precautions and requirements in the following chapters:
"2 General safety
"8.5 Preparing water
NOTICE
Do NOT use excessive force when connecting the piping. Deformation of the piping
can cause malfunctioning of the unit.
To facilitate service and maintenance, 2 shut-off valves and 1 overpressure bypass
valve are provided. Mount the shut-off valves on the space heating water inlet and
space heating water outlet. To ensure the minimum flow rate (and prevent
overpressure), install the overpressure bypass valve on the space heating water
outlet.
1 Install the shut-off valves on the space heating water pipes.
2 Screw the indoor unit nuts on the shut-off valve.
3 Connect the domestic hot water in and out pipes to the indoor unit.
a2
b2
b1
a1 Space heating/cooling – Water IN (screw connection, 1")
a2 Space heating/cooling – Water OUT (screw connection, 1")
b1 DHW – Cold water IN (screw connection, 3/4")
b2 DHW – Hot water OUT (screw connection, 3/4")
4 Install the following components (field supply) on the cold water inlet of the
DHW tank:
a
4
precautions" [
 10]
4
piping" [
 102]
a1
*e
*f
d
*g
b2
b1
8
Piping installation
|
c
a
Installer reference guide
109