Daikin ERLA11D V3 Series Installer's Reference Manual page 196

Hide thumbs Also See for ERLA11D V3 Series:
Table of Contents

Advertisement

11
|
Configuration
Installer reference guide
196
[9-0D]/[9-0E]=0
a (kPa)
[9-0D]/[9-0E]=2/6
a (kPa)
[9-0D]/[9-0E]=4/8
a (kPa)
a External static pressure
b Water flow rate
Pump outside range
When the pump operation function is disabled the pump will stop if the outdoor
temperature is higher than the value set by the Space
temperature [4‑02] or if the outdoor temperature drops below the value set by
the Space cooling off temperature [F‑01]. When the pump operation is
enabled, the pump operation is possible at all outdoor temperatures.
#
Code
[4.9]
[F-00]
Increase around 0°C
Use this setting to compensate for possible heat losses of the building due to the
evaporation of melted ice or snow. (e.g. in cold region countries).
[9-0D]/[9-0E]=1/5
a (kPa)
b (l/min)
[9-0D]/[9-0E]=3/7
a (kPa)
b (l/min)
b (l/min)
Pump operation:
0: Disabled if outdoor temperature is higher
than [4‑02] or lower than [F‑01] depending on
heating/cooling operation mode.
1: Possible at all outdoor temperatures.
b (l/min)
b (l/min)
heating
Description
ERLA11~16D + EBVH/X11+16S18+23D
Daikin Altherma 3 R F
4P643602-1B – 2022.05
off

Advertisement

Table of Contents
loading

Table of Contents